SMART-RF-POLICY 21 - 7
21.1.5 coverage-hole-recovery
smart-rf-policy
Enables recovery from coverage hole errors
Supported in the following platforms:
RFS7000
RFS6000
RFS4000
AP71xx
AP650
AP6511
AP6532
Syntax
coverage-hole-recovery {client-threshold|coverage-interval|interval|
snr-threshold}
coverage-hole-recovery client-threshold [2.4Ghz|5Ghz] <1-255>
coverage-hole-recovery [coverage-interval|interval] [2.4Ghz|5Ghz] <1-120>
coverage-hole-recovery snr-threshold [2.4Ghz|5Ghz] <1-75>
Parameters
Example
rfs7000-37FABE(config-smart-rf-policy-test)#coverage-hole-recovery snr-threshold
5GHz 1
rfs7000-37FABE(config-smart-rf-policy-test)#
client-threshold|coverage-
interval|interval|
snr-threshold}
client-threshold <1-255> – Specifies the minimum number of clients
below SNR threshold required for coverage hole recovery. Select the
number of clients between 1 and 255.
coverage-interval <1-120> – Specify the interval at which recovery
should be performed after coverage hole is discovered. Select a interval
coverage- interval value between 1 and 120 seconds
interval <1-120> – Specify the interval at which a coverage hole recovery
should be performed before coverage hole is detected. Select a interval
value between 1 and 120 seconds
snr-threshold <1-75> – Specify the SNR threshold below which coverage
recovery is initiated. Select a SNR threshold value between 1 and 75
The following bandwidth is common for all the above:
2.4GHz – 2.4GHz band
5GHz – 5GHz band
Page view 830