INTRODUCTION 1 - 13
rfs7000-37FABE(config-profile-default-ap7131)#show context
1.4.5 Change the default profile by creating vlan 150 and mapping to ge3 Physical interface
Logon to the controller in config mode and follow the procedure below:
rfs7000-37FABE(config-profile-default-rfs7000)# interface vlan 150
rfs7000-37FABE(config-profile-default-rfs7000-if-vlan150)# ip address
192.168.150.20/24
rfs7000-37FABE(config-profile-default-rfs7000-if-vlan150)# exit
rfs7000-37FABE(config-profile-default-rfs7000)# interface ge 3
rfs7000-37FABE(config-profile-default-rfs7000-if-ge3)# switchport access vlan 150
rfs7000-37FABE(config-profile-default-rfs7000-if-ge3)# commit write
[OK]
rfs7000-37FABE(config-profile-default-rfs7000-if-ge3)# show interface vlan 150
Interface vlan150 is UP
Hardware-type: vlan, Mode: Layer 3, Address: 00-15-70-37-FA-BE
Index: 8, Metric: 1, MTU: 1500
IP-Address: 192.168.150.20/24
input packets 43, bytes 12828, dropped 0, multicast packets 0
input errors 0, length 0, overrun 0, CRC 0, frame 0, fifo 0, missed 0
output packets 0, bytes 0, dropped 0
output errors 0, aborted 0, carrier 0, fifo 0, heartbeat 0, window 0
collisions 0
1.4.5.1 Viewing Configured APs
To view previously configured APs, enter the following command:
rfs7000-37FABE(config)#show wireless ap configured
1.4.6 Remote Administration
A terminal server may function in remote administration mode if either the terminal services role is not installed on the
machine or the client used to invoke the session has enabled the admin controller.
A terminal emulation program running on a computer connected to the serial port on the controller. The serial port is
located on the front of the controller.
A Telnet session through a Secure Shell (SSH) over a network. The telnet session may or may not use SSH depending
on how the wireless controller is configured. Motorola Solutions recommends using SSH for remote administration
tasks.
1.4.6.1 Configuring telnet for Management Access
Login through the serial console. Perform the following:
1. A session generally begins in the USER EXEC mode (one of the two access levels of the EXEC mode).
2. Access the GLOBAL CONFIG mode from the PRIV EXEC mode
rfs7000-37FABE> en
rfs7000-37FABE# configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
3. Go to ‘default-management-policy’ mode.
rfs7000-37FABE(config)# management-policy ?
rfs7000-37FABE(config)# management-policy default
rfs7000-37FABE(config-management-policy-default)#
4. Enter Telnet and the port number at the command prompt. The port number is optional. The default port is 23. Commit
the changes after every command. Telnet is enabled.
rfs7000-37FABE(config-management-policy-default)# telnet
rfs7000-37FABE(config-management-policy-default)# commit write