7 - 66 WiNG CLI Reference Guide
7.1.21.9 power
Interface Config Instance
Invokes PoE commands to configure the PoE power limit and port priority. By default, the value for a GE port is set to low.
Power is applied in order of priority, power overlaods are removed in the reverse order of priority.
Supported in the following platforms:
• RFS6000
• RFS4000
• AP71xx
• AP650
• AP6511
• AP6532
Syntax
power {limit <0-40>|prority}
power priority [critical|high|low]
Parameters
Usage Guidelines
Use [no] power to rollback the PoE configurations and set back the default configuration
Example
rfs7000-37FABE(config-profile-default-rfs7000-if-ge1)#power priority critical
% Error: No POE support on device type [rfs7000].
rfs7000-37FABE(config-profile-default-rfs7000-if-ge1)#
Switch Note: This command is not supported on the RFS7000 controller.
limit <0-40> Sets the power limit on the given port to the stated power in Watts. Select
the power limit value between 0-40 (Watts). It actually limits to 29.7W
priority [critical|high|low] Sets PoE priority for port
• critical – Sets the PoE priority as a critical priority
• high – Sets the PoE priority as a high priority
• low – Sets the PoE priority as a low priority