Testing a telecoms link Chapter 8 Troubleshooting
phn-1115_006v000
8-20
Sep 2010
Figure 8-5 Telecoms page
Table 8-3 Telecoms Loopback values
Value Meaning
None This is the required setting for an operational link.
Copper Connects the received data on a given telecoms interface to
the transmit interface.
May be used, in conjunction with a Bit Error Rate Tester, to
confirm that the correct connections have been made to the
ODU. This mode cannot be used for resistance tests, as it is
only capable of looping back valid telecoms signals.
Wireless Sends the telecoms data received from the wireless link back
across the link on the same telecoms channel.
The link may be checked using, for example, a Bit Error Rate
Tester to ensure that no errors are detected.