PTP 300 and PTP 500 Series User Guide Web-based management
phn-1115_006v000
Sep 2010
7-7
Alarm display
Whenever system alarms are outstanding, a yellow warning triangle is displayed on
the navigation bar. The warning triangle is visible from all web pages. Click the
warning triangle to return to the System Summary page and view the alarms.
The example in Figure 7-4 shows th
e warning triangle in the navigation bar and the
Install Arm State alarm displayed in the System Summary page.
The alarms are defined in Table 7-3.
Figure 7-
4 Alarm warning triangle
Table 7-3 System alarms
Alarm Meaning
Region Code The region code prohibits the wireless unit from operating
outside the regulated limits. An invalid region code indicates
a corrupted license key. Note that a change of state may
generate an SNMP trap and/or SMTP email alert.
Install Status A non-OK value indicates that signaling was received with the
wrong MAC address. Note that it is very unusual to detect
this, because units with wrongly configured Target MAC
Address will normally fail to establish a wireless link.
However, rare circumstances may establish a partial wireless
link and detect this situation. NB: A non-OK value on start-up,
or a change of value during operation, may generate an
SNMP trap and/or SMTP email alert.