Task 1: Connecting to the unit Chapter 6 Configuration and alignment
phn-1115_006v000
6-4
Sep 2010
Connecting to the PC and powering up
To connect the ODU to the PC and power up the unit, proceed as follows:
Procedure 6-2 Power up and log into the unit
1
Check that the ODU and PIDU Plus are correctly connected.
2
Connect the PC Ethernet port to the LAN port of the PIDU Plus using a
standard (not crossed) Ethernet cable.
3
Apply mains or battery power to the PIDU Plus. The green Power LED
should illuminate continuously.
4
After about 45 seconds, check that the orange Ethernet LED starts with
10 slow flashes.
5
Check that the Ethernet LED then illuminates continuously.
NOTE
If the Power and Ethernet LEDs do not illuminate correctly, refer to Testing
link end har
dware on page 8-2.
Logging into the web interface
NOTE
If a PTP 300 or PTP 500 link has been purchased, one unit will be factory
configured as a Master unit with an IP address of 169.254.1.2. The other
unit will be factory configured as a Slave unit with an IP address of
169.254.1.1.
If a single PTP 300 or PTP 500 unit has been purchased, it will be factory
configured as a Slave unit with an IP address of 169.254.1.1.