Installing a GPS receiver for PTP-SYNC Chapter 5 Installation
phn-1115_006v000
5-38
Sep 2010
5
Insert the eight contacts into the connector body in accordance with
Table 5-1. It
is easiest to insert the pins from the inside out, in the order
12, 11, 9, 5, 4, 3, 2, 1. Push the contacts in so that the shoulder on the
contact fits into the hole in the connector shell. When all contacts have
been fitted, push them in further to engage with the locking mechanism
in the connector shell. This can be done by applying pressure to the
contact with a small diameter stiff object, such as tweezers.
If a contact is pushed in to the point where the locking mechanism
engages before all of the contacts have been inserted it will limit the
amount of room available to fit the remaining contacts, requiring harder
bends to be applied.
6
Fit the adaptor to the connector shell. The plastic ring fits inside the
rubber boot and ensures a tight fit when the adaptor body is clipped onto
the connector shell. Be aware that the adaptor body is a hard push fit
onto the connector shell.
7
Fit the strain relief clip.
8
Connect the adapter to the GPS, then wrap a layer of self-amalgamating
tape, starting 25mm below the bared back outer of the cable and
finishing at the GPS housing.