PTP 300 and PTP 500 Series User Guide Grounding and lightning protection
phn-1115_006v000
Sep 2010
2-19
Protection requirements for a wall installation
If the ODU is to be mounted on the wall of a building, then in addition to the general
protection requirements (above), the following requirements must be observed:
The equipment must be lower than the top of the building or its lightning air
terminal.
The building must be correctly grounded.
Schematic examples of wall installations are shown in Figure 2-4.
Figu
re 2-
4 Grounding and lightning protection on wall