System management Chapter 1 Product description
phn-1115_006v000
1-48
Sep 2010
Recovery mode
The PTP 300 and PTP 500 recovery mode provides a means to recover from serious
configuration errors including lost or forgotten passwords and unknown IP addresses.
Recovery mode also allows new main application software to be loaded even when the
integrity of the existing main application software image has been compromised. The
most likely cause of an integrity problem with the installed main application software
is where the power supply has been interrupted during an earlier software upgrade.
The ODU operates in recovery mode in the following circumstances:
When a checksum error occurs for the main application software image.
When the PIDU Plus recovery button is pressed at the same time as the ODU is
rebooted or power cycled.
Recovery mode options
Options in recovery mode are as follows:
Load new main application software.
Reset all configuration data to factory default. This option resets IP and Ethernet
configuration.
Reset IP and Ethernet configuration to factory default.
Reboot with existing software and configuration.
NOTE
If recovery mode has been entered because of a checksum error, by default
the ODU will reboot with existing software and configuration, following a 30
second wait.
The recovery software image is installed during manufacture of the ODU and cannot
be upgraded by operators.
For detailed instructions on using the recovery mode, see Using recovery mode on
pag
e
7-53.