PTP 300 and PTP 500 Series User Guide Installing the ODU
phn-1115_006v000
Sep 2010
5-15
Selecting a position for the ODU (connectorized)
If the ODU is connectorized, select a mounting position that gives it maximum
protection from the elements, but still allows easy access for connecting and
weatherproofing the cables. To minimize cable losses, select a position where the
antenna cable lengths can be minimized. If separate antennas are being deployed, it is
not necessary to mount the ODU at the mid point between the antennas.
Mounting the ODU
To mount the ODU, proceed as follows:
Procedure 5-4 Mounting the ODU
1
Attach the ODU bracket strap to the pole using M8 x 70 mm bolts, M8
flat washers and M8 coil washers.
Tighten to ensure the assembly grips, but can be adjusted on the pole.
2
Use the integral safety loop (Figure 5-4) to hois
t the ODU up to the
bracket, observing the precautions described in Checks and safety
prec
autions on page 5-13.
3
When the ODU is in position, use the safety loop as a fixing point to
secure a permanent lanyard from the supporting structure to the ODU,
as a precaution against mounting failure.