Installing connectorized antennas Chapter 5 Installation
phn-1115_006v000
5-18
Sep 2010
4
When dressing the antenna cables, form drip loops near the lower ends
(Figure 5-7). These e
nsure that water is not constantly channeled
towards the connectors.
5
Weatherproof the ODU joints using self-amalgamating tape under a layer
of PVC tape (Figure 5-8). We
atherproof the antenna joints in the same
way (unless the antenna manufacturer specifies a different method).
6
Ground the antenna cables to the supporting structure at the correct
points (Figure 5-9).
NOTE
A mast or tower may require additional grounding points, as
specified in Protection requirements for a mast or tower installation
on page 2-17.
7
Dress the antenna cables and fix them using cable ties, cleats or PVC
tape.
CAUTION
Ensure that no undue strain is placed on the ODU or antenna
connectors. Ensure that the cables do not flap in the wind, as
flapping cables are prone to damage and induce unwanted vibrations
in the supporting structure.