Preparing and using drop cable Chapter 5 Installation
phn-1115_006v000
5-10
Sep 2010
To ground the drop cable to a metal structure, proceed as follows:
Procedure 5-3 Ground the drop cable
1
Remove 60mm (2.5inches) of the drop cable outer jacket.
2
Cut 38mm (1.5 inches) of rubber tape (self amalgamating) and fit to the
ground cable lug. Wrap the tape completely around the lug and cable.
3
Fold the ground wire strap around the drop cable screen. Fit cable ties and
tighten with pliers.