Motorola MVME172 User Manual Page 74

  • Download
  • Add to my manuals
  • Print
  • Page
    / 354
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 73
1-56 Computer Group Literature Center Web Site
Board Description and Memory Maps
1
SCSI Parity Error
Note The 400/500-Series MVME172 models do not contain parity
DRAM.
Description:
Parity error detected while the 53C710 was reading DRAM.
MPU Notification:
53C710 Interrupt.
Status:
53C710 DMA Status Register 53C710 DMA Interrupt Status Register
MC2 chip SCSI Error Status Register ($FFF4202C).
Comments:
53C710 interrupt enables are controlled in the 53C710 and in the MC2
chip SCSI Interrupt Control Register ($FFF4202F).
SCSI Off-Board Error
Description:
Error encountered while the 53C710 was attempting to go to the VMEbus.
MPU Notification:
53C710 Interrupt.
Status:
53C710 DMA Status Register 53C710 DMA Interrupt Status Register
MC2 chip SCSI Error Status Register ($FFF4202C).
Comments:
53C710 interrupt enables are controlled in the 53C710 and in the MC2
chip SCSI Interrupt Control Register ($FFF4202F).
SCSI LTO Error
Description:
Local Bus Time-out occurred while the 53C710 was local bus master.
Page view 73
1 ... 73 74 75 ... 354

Comments to this Manuals