![](/jointfilesconvert/1248049/bg141.png)
Programming Model
http://www.mcg.mot.com/literature 5-31
5
Scrub Address Counter (Bits 7-4)
This register reflects the current value in the Scrub Address Counter bits
7-4.
Error Logger Register
SBE SINGLE BIT ERROR is set when the last error logged
was due to a single bit error. It is cleared when a 1 is
written to the ERRLOG bit. The syndrome code reflects
the bit in error. (Refer to the section on Syndrome
Decode.)
MBE MULTIPLE BIT ERROR is set when the last error logged
was due to a multiple bit error. It is cleared when a 1 is
written to the ERRLOG bit. The syndrome code is
meaningless if MBE is set.
ERA This bit provides status for a function that is not currently
used in the MCECC.
ADR/SIZ 1st $FFF43058/2nd $FFF43158 (8-bits)
BIT 31 30 29 28 27 26 25 24
NAME SAC7SAC6SAC5SAC40000
OPER R/WR/WR/WR/WRRRR
RESET 0 PLS0 PLS0 PLS0 PLSXXXX
ADR/SIZ 1st $FFF4305C/2nd $FFF4315C (8-bits)
BIT 31 30 29 28 27 26 25 24
NAME ERRL
OG
ERD ESCR
B
ERA EALT 0 MBE SBE
OPER R/CRRRRRRR
RESET 0 PLS 0 PLS 0 PLS 0 PLS 0 PLS X 0 PLS 0 PLS