Field Field Default: 1
Note: The IRD does not display this field when the waveform is set to Transmitted
or Disabled.
The Field field allows the user to select the field on which the VITS is reinserted by
the receiver. Press the
4
button until the cursor is at the Field label, and press the
ENTER button to move into the field. Press the
56
buttons to select the desired
option (Field 1 or Field 2) and press the ENTER button to confirm the selection and
exit the field.
Line Field Default: 17
Note: The IRD does not display this field when the waveform is set to Transmitted
or Disabled.
Press the
4
button until the cursor is at the Line label, and press the ENTER button
to move into the field. Press the
56
buttons to display the options (17 or 18).
Press the ENTER button to confirm the selection and exit the field.
Ad Insertion Test Menu
The Ad Insertion Test menu allows the user to test the cue tones and turn the relays
on and off. Ad insertion signals are generated by the DSR-4530, but controlled by
the uplink programmer. Local cable companies use ad insertion signals to control
and to queue the insertion of commercials in cable headends. There are two ways to
provide ad insertion:
• A dedicated digital DTMF differential output for cue tones.
• A dedicated contact closure relay.
Press the
56
buttons until the Ad Insertion Test menu appears (shown below).
Caution: Output to the customers may be interrupted. When turned on, the ad
insertion signals can be sent to the local headend equipment.
E Color Bar 1 17
VITS Waveform Field Line
E Off Off
AD INSERTION TEST Cue Tone Relay