Test Descriptions
3-18 167Bug Debugging Package UserÕs Manual
3
Clock Function - CLK
This test verifies the functionality of the Real Time Clock (RTC). This test does
not check clock accuracy.
This test requires approximately nine seconds to run. At the conclusion of the
test, nine seconds are added to the clock time to compensate for the test delay.
Because the clock can only be set to the nearest second, this test may induce ±
one second of error into the clock time.
Command Input:
167-Diag>RTC CLK
Response/Messages:
After the command has been issued, the following line is printed:
RTC CLK: MK48T0x Real Time Clock............. Running --->
If all parts of the test are completed correctly, then the test passes.
RTC CLK: MK48T0x Real Time Clock............. Running ---> PASSED
If the test fails, then the display appears as follows.
RTC CLK: MK48T0x Real Time Clock............. Running ---> FAILED
(error message)
Here, (error message) is one of the following:
If the check for low battery fails.
RTC low battery
Note
The Low Battery test only assures Battery OK if the
MK48T02 (used on other boards) has not been written since
powerup. The Battery test is performed here in case the
debugger currently in use does not perform a Low Battery
test on powerup. Although the MK48T08 does not support
the internal battery voltage check (BOK), the BOK flag
status check algorithm is performed by this test on all parts.
The RTC time registers are configured for constant updating by the clock
internal counters. The seconds register is read initially and then monitored
(read) to verify that the seconds value changes. A predetermined number of
reads are made of the seconds register.