Motorola MVME712A/D3 User Manual Page 190

  • Download
  • Add to my manuals
  • Print
  • Page
    / 239
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 189
Test Descriptions
3-146 167Bug Debugging Package UserÕs Manual
3
+12VDC Fuse - FUSE
This test verifies that the +12VDC Fuse indicator (via the VMEChip2) is true
(fuse present). The MVME167 supplies the +12VDC power to the Ethernet
transceiver interface through a fuse. The green +12VDC (LAN power) LED
(part of DS3) lights when power is available to the transceiver interface.
Command Input:
167-Diag>LANC FUSE
Response/Messages:
After the command has been issued, the following line is printed:
LANC FUSE: +12VDC Fuse....................... Running --->
If all parts of the test are completed correctly, then the test passes:
LANC FUSE: +12VDC Fuse....................... Running ---> PASSED
If any failures occur, the following is displayed (more descriptive text then
follows):
LANC FUSE: +12VDC Fuse....................... Running ---> FAILED
(error message)
This failure is the result of the fuse indicator (via the VMEChip2) being false
(fuse not present or blown):
FUSE (+12VDC) Status Bit Error: Expected =0, Actual =1
Page view 189
1 2 ... 185 186 187 188 189 190 191 192 193 194 195 ... 238 239

Comments to this Manuals

No comments