Test Descriptions
3-8 167Bug Debugging Package UserÕs Manual
3
Data Patterns - PATS
If the test address range (test range) is less than 8 bytes, the test immediately
returns pass status. The effective test range end address is reduced to the next
lower 8-byte boundary if necessary. Memory in the test range is filled with all
ones ($FFFFFFFF). For each location in the test range, the following patterns
are used:
$00000000
$01010101
$03030303
$07070707
$0F0F0F0F
$1F1F1F1F
$3F3F3F3F
$7F7F7F7F
Each location in the test range is, individually, written with the current pattern
and the 1's complement of the current pattern. Each write is read back and
verified. This test is coded to use only 32-bit data entities.
Command Input:
167-Diag>RAM PATS
or:
167-Diag>SRAM PATS
Response/Messages:
Note that in all responses shown below, the response "RAM " is RAM or SRAM,
depending upon which test set is being performed. After the command has
been issued, the following line is printed:
RAM PATS: Patterns................... Running --->
If all parts of the test are completed correctly, then the test passes.
RAM PATS: Patterns................... Running ---> PASSED
If the test fails, then the display appears as follows.
RAM PATS: Patterns................... Running ---> FAILED
Data Miscompare Error:
Address =________, Expected =________, Actual =_________