Motorola MVME712A/D3 User Manual Page 105

  • Download
  • Add to my manuals
  • Print
  • Page
    / 239
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 104
ECC Memory Board (MCECC) Tests
MVME167BUG/D3 3-61
3
Single-Bit-Error - SBE
This function tests the ECC board's ability to correct single-bit-errors. It fills a
memory area with random data containing a "single-bit-error" in each word.
All of the tested memory area is then verified with error correction enabled, so
that the data will be "corrected" during the read operation.
Command Input:
167-Diag>MCECC SBE
Response/Messages:
If "verbose" execution has been configured with the CF command, something
will be printed on the status line to let you know that the test is still running.
The first message indicates that the ECC checkbits are being initialized. The
format of the status update is: ________
x
# where the "________" portion is
the current address being accessed, the "x" is replaced by either "
w" or "r"
depending on whether the current pass through memory is write/read. The
"#" indicates the memory board number being tested.
ECC SBE: ECC Single-Bit-Error.......... Running ---> bd # init
ECC SBE: ECC Single-Bit-Error.......... Running ---> ________ x#
ECC SBE: ECC Single-Bit-Error.......... Running ---> PASSED
If an error is detected during the operation of the test, one of the following
messages is displayed:
Failures due to the scrubber during checkbit initialization:
Timed out waiting for scrubber to start, bd #_ (status __)
Timed out waiting for scrubber to stop, bd #_ (status __)
Errors due to single-bit-errors not being corrected properly:
Address=________, Expected=________, Actual=________
The test ends with:
ECC SBE: ECC Single-Bit-Error............. Running ---> FAILED
Page view 104
1 2 ... 100 101 102 103 104 105 106 107 108 109 110 ... 238 239

Comments to this Manuals

No comments