Technician Mode
68P02953C05 12-9
12.3.2.2. Oscillator Calibration Procedure
CAUTION
During the calibration procedure, the radio transmits in CW
(Continuous Wave) mode via its RF output.
1. Prior to calibration, set an external reference frequency with the highest possible value.
Perform the manual oscillator calibration in transmit mode according to the following
steps:
2. For a standard oscillator (PENDULUM), load the frequency word from the radio. For a
high stability oscillator (OCXO), load the frequency and the temperature words from the
radio, or, following oscillator replacement, type the words which appear on the oscillator
package.
3. To start manual calibration in transmit mode, press the Start Calibration button. The
RSS sends a message to the radio, which in turn starts transmitting on the selected
transmit frequency channel.
4. Read the RF counter measurement.
5. Press the Stop Calibration button and compare the measurement result to the Radio
Specifications.
6. If the measurement result does not match the specifications, modify the frequency word
and go back to step 2. (It is not recommended to change the temperature word.)
7. If the measurement result matches the specifications, press the OK button. A message to
load the measured frequency into the radio using the Write Device command appears on
the screen.
12.3.3. Manual Calibration - Receive Mode
12.3.3.1. Oscillator Calibration Setup
To perform manual oscillator calibration, connect the setup illustrated below:
EXTERNAL
REFERENCE
AUDIO
ANALYZER
MICOM2 RADIO
UNDER TEST
ACCESSORY PLUG ANTENNA OUT
AUDIO
GND
RSS
Figure 12-12. Oscillator Calibration Setup - Manual Receive Mode