Technician Mode
12-4 68P02953C05
Table 12-1. Power Calibration Levels
Power Level Power Word Range Recommended
Power [Watt]
Tuner
0 to 60 3
1 KWatt
0 to 70 10
Low 0 to lower limit of Medium
25
Medium Upper limit of Low to lower limit of High
60
High Upper limit of Medium to lower limit of Max
100
Max Upper limit of High to 127
125
3. To transmit power with the current calibration parameters, press the Start Calibration
button. Upon starting calibration, the Communication Progress message box appears on
the screen. Click the Abort button if you want to stop calibration.
Figure 12-5. Communication Progress Window
If there is no response from the radio, or the communication parameters (baud rate or
communication ports) are not compatible a Communication Failure message appears.
4. Read the Power Meter measurement.
5. Press the Stop Calibration button and compare the measurement result with the
recommended value in Table 12-1.
6. If the measurement result does not match the recommended value, go back to step 2.
7. If the measurement equals the recommended value in Table 12-1, select the next
frequency range and repeat the procedure.