Motorola Confidential Proprietary
TDMA M3090/M3097Test Procedures
44
TX ST Deviation Test
Communications Analyzer Setup:
• Select TX button from the Screen Con
trol panel
• PWR is measured in dBm
• Set Frequency Measurement to auto
or manual (display will show TX Freq.
Error)
• Set TX frequency to 834.990 MHz
• Set IF filter to 230 kHz
• Set AF Filter 1 to 50 Hz
• Set AF Filter 2 to 15 kHz
• Set AF gen1 for 1 kHz frequency at
6V level (output will go to the audio
port)
Test Mode Commands:
11333# Load synthesizer to channel
333
122# Set power level to power step
2
05# Turn on transmit carrier
14# Enable signaling tone
View FM Deviation for reading.
The ST deviation measured on the com-
munications analyzer should be
between 7.2 kHz - 8.2 kHz .
The demodulated signal on the com-
munications analyzer should have
an audio frequency of 10 kHz.
TX TEST
dB
TX Frequency
834.9900
MHZ
Tx Power
27.49
dBm
FM Deviation
7.890
KHz
10.0000
KHz
AF Freq
Tune Mode
Auto / Manual
Tune Freq
834.990000
MHz
Tx Pwr Zero
Zero
Input Port
RF In / Ant
If Filter
230 KHz
Ext TX Key
On / Off
AF Anl In
FM Demod
Filter 1
50 Hz HPF
Filter 2
15 KHz LPF
De-Emphasis
750 us / Off
Detector
Pk +- Max
AF Gen 1 Freq
1.0000
KHz
AF Gen 1 Lvl
6.00
V
To Screen
RF GEN
RF ANL
AF ANL
SCOPE
SPEC ANL
ENCODER
DECODER
RADIO INT
More
Figure 27. TX Test Screen