TDMA M3090/M3097: Charger
B32
Description
CHG-
R1305
SW_EXT_B+
Q1304A
Q1304B
B+
CR1300
SW_EXT_B+
BATT+
CHRGC
C1300
SW_EXT_B+
ISENSE
R1300
Q1301
CR1301
Q1302
BACKLIGHTING
Q1401
Q1400
R1306
BKLT
BATT+
BATT_FDBK_EN
BATT_FDBK
Q1303
The internal charger will be activated only when there is an external power source of 8.0V ± 0.4V for the fast charger, 7.05V ±0.35V for the midrate charger, a Motorola
battery is attached, and BATT_FDBK is enabled. As SW_EXT_B+ passes thru R1566, U1500 (GCAP) reads the charge current for proper control of the charger. CHRGC
controls the rate of charge to the batteries by varying the gate biasing of Q1561. The output of Q1561 is split into two different sections. The one section is the
BATT_FDBAK line. BATT_FDBK_EN switches Q642 on or off to disable or enable BATT_FDBAK. When BATT_FDBK is not available, the external supply will
lower it's supply to a normal operating voltage and the internal charger will be turned. The second section is the line to charge the batteries.
DHFA and CLA are detected by internal pulldown resistors, 3.0Kohm on the MAN_TEST line and 56Kohm on the CMP line for DHFA, 33.2Kohm on the MAN_TEST
line for CLA. DHFA/CLA EXTB+ voltage tracks 1.4V above the battery voltage to a maximum of 7.5VDC as long as BATT_FDBK is enabled. If there is no
BATT_FDBK, EXTB+ from the CLA or DHFA is 5.4VDC.
CHG- is there to prevent alkaline batteries from ever receiving charge current, which would be a safety concern. Rechargeable Motorola battery packs have this pin tied to
BATT_GND. A low at CHG- would switch on Q1304A and switch off Q1304B allowing for battery charging. A high would disable battery charging by forcing the gate
of Q1302 with external B+ causing Q1302 to turn off.
Q1301 is simply a switch that determines which power source is going to be used. When SW_EXT_B+ (external B+) is present, Q1301 will be switched off not allowing
BATT+ to be the power source. If SW_EXT_B+ is not present, Q1301 will switch on, letting BATT+ be the power source.
The display backlighting is controlled by the Call processor (U1000). U1000 sends a control signal via the BACKLIGHTING line. A high state at the BACKLIGHTING
line will switch Q1401 on. This will complete the display circuit's path to ground. As a result, the display backlighting will be illuminated.