TDMA M3090/M3097Test Procedures
38
Set up for Analog call
Registration
1. Put the Test Set in Active state
by selecting Active from the list on the
left side of the screen.
2. Select Data from the Data/Meas
field. This is the default mode.
3. Select Register from the list to
register phone.
4. If the registration message has
been received, the Test Set will display
registration data in the upper half of the
screen as shown in the sample screen
above.
Page
1 Select page from the list on the left
side of the screen.
2 If the mobile responds, you will
see the Access annunciator light briefly.
3 Answer the call by raising the flip
or press SEND on the mobile to start the
conversation.
4 The Connect annunciator lights.
This is the Connect state.
Origination
1 Dial the desired phone number on
the mobile station and press SEND.
2 The Access annunciator will light
while the Test Set signals the mobile on
the assigned voice channel.
3 The connect annunciator will light
if the mobile properly signals the Test
Set.
Select CALL CNTL from the To Screen
Select System type: AMPS
Zero the RF Power meter in the:
Call Config Screen
Set Amplitude to: -50 dBm
Set SID: Your phones System
ID
Select: Active
Voice Channel Assignment
Type:
Chan: 212
Pwr Lvl: 4
SAT: 5970Hz
CALL CONTROL
Display
Active
Register
Page
Access
Connect
Order
MS Id
Active
Register
Page
Handoff
Release
Chng PL 0
Phone Num
1111111111
System Type
DCCH
Cntrl Chan
Amplitude
-50.0
SID
231
To Scre en
CALL CNT L
CALL CNFG
ANLG MEAS
SPEC ANL
DIG MEAS
More
Data / Meas
dBm
Traffic Chan Assisgnment
Chan : -
Pwr Lvl : -
SAT :
Phone : 111-111-1111
ESN (dec) : 156-4460397
ESN (hex) : 9C440F6D
SCM : Class IV, Continuous, 25 MHz
334
212
0
5970Hz