Motorola M3097 Service Manual Page 51

  • Download
  • Add to my manuals
  • Print
  • Page
    / 133
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 50
Motorola Confidential Proprietary
TDMA M3090/M3097Test Procedures
40
TX Power Out Test
TX TEST
dB
TX Frequency
834.9900
MHZ
Tx Power
27.49
dBm
FM Deviation
11.58
KHz
1.00000
KHz
AF Freq
Tune Mode
Auto / Manual
Tune Freq
834.990000
MHz
Tx Pwr Zero
Zero
Input Port
RF In / Ant
If Filter
230 KHz
Ext TX Key
On / Off
AF Anl In
FM Demod
Filter 1
50 Hz HPF
Filter 2
15 KHz LPF
De-Emphasis
750 us / Off
Detector
Pk +- Max
AF Gen 1 Freq
1.0000
KHz
AF Gen 1 Lvl
6.00
V
To Screen
RF GEN
RF ANL
AF ANL
SCOPE
SPEC ANL
ENCODER
DECODER
RADIO INT
More
Communications Analyzer Setup:
• Select TX button from the Screen
Control panel
• PWR is measured in dBm
• Set Frequency Measurement to auto
or manual (display will show TX Freq.
Error)
• Set TX frequency to 834.990 MHz
• Set IF filter to 230 kHz
• Set AF Filter 1 to 50 Hz
• Set AF Filter 2 to 15 kHz
• Set AF gen1 for 1 kHz frequency at
6V level (output will go to the audio
port)
Test Mode Commands:
11333# Loads synthesizer to chan
nel 333
12X# Set power level to step X,
where X is a power level
from 1 to 7.
05# Turns on transmit carrier
The TX Power Out specification for each
portable power level is as follows:
Power Step 2 25dBm - 26dBm
Power Step 3 20.5dBm - 23.5dBm
Power Step 4 17.0dBm - 20.0dBm
Power Step 5 13.0dBm - 16.5dBm
Power Step 6 9.0dBm - 12.5dBm
Power Step 7 5.5dBm - 9.0dBm
Refer to the TX troubleshooting section
for radios not within the pass specifica-
tions.
Note: When taking measurements, re-
member to compensate for cable loss.
Figure 23. TX Test Screen
TX Power Out Test
Page view 50
1 2 ... 46 47 48 49 50 51 52 53 54 55 56 ... 132 133

Comments to this Manuals

No comments