Digital Output Module
30 of 56 ICD-13/05 ICD 13—Standard Controller
12.0 Digital Output Module
A Digital Output card is also available for driving higher voltage or power outputs, typ-
ically to operate relays or solenoids.
12.1 Description
The Standard Controller digital output module is the Xycom XVME-220. The card is
supplied with a manual which describes the connections and jumper settings, program-
ming interface and full circuit diagrams[15]. This card provides 32 opto-isolated open-
collector outputs.
12.2 Installation
Only a single XVME-220 card is assumed in the standard EPICS distribution although
more are allowed. See the manual page 2-2 for a diagram giving the jumper and switch
locations, which should be set as follows:
TABLE 19. Digital Output module specifications
Item Description
Model Number XVME-220
Manufacturer Xycom
Input Power 5 Volts @ 1.62 Amps (typ.).
Connections 2 off IDC50 plugs on front panel.
Output Characteristics I
ol
= 100 mA max.
V
oh
= 30 Volts max.
Dimensions 1 slot x 6U
Operating Temperature 0° to 65° C
Humidity 5% to 95% non-condensing
TABLE 20. XVME-220 Switch and Jumper Setting
J/S Configures Setting
S1 1 A10 Closed
2A11 Open
3A12 Closed
4A13 Closed
5A14 Open
6A15 Open
7 User Mode Access Closed
8 Short Address Closed