Motorola MVME167 User Manual Page 24

  • Download
  • Add to my manuals
  • Print
  • Page
    / 56
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 23
Stepper Motor Controller
24 of 56 ICD-13/05 ICD 13—Standard Controller
Home Input
+5V and Ground
10.1 Description
The Standard Controller stepper motor controller is the Oregon Microsystems VME8-
8 Intelligent Motion Controller. The OMS card comes with a User’s Manual[13] which
describes the card, jumper settings and external connections, the programming interface
and firmware command structure, Oregon’s warranty and repair procedures and a full
circuit diagram.
10.2 Installation
Page 3-7 of the Users Manual [13] contains a diagram which should be referred to when
setting the jumpers to the following positions:
Jumper
J34 is not mentioned the table above because it is dependent on the particular
application, setting the polarity of the limit inputs for the various motor axes.
The standard EPICS distribution can support up to 8 OMS cards, and the addresses for
these are selected using the A7 to A4 pins of jumper J27. The test instructions below
assume that the module is set to card 0; adjustments to the addresses given will be
needed if a different card number is used. The different settings are as follows:
The I/O connections to the OMS card are all made through the P2 backplane connector.
The simplest way to make these connections is to use an IDC connector, 64 way
DIN41612 using rows A and C. The IDC cable can be split into groups of 8 conductors
with each group comprising the signals for one motor axis (see page 4-2 of the Users
Manual for the pin assignments).
The module test for the OMS card presented here does not attempt to check the special-
ized functionality of the card at all, it just verifies that it is possible to send commands to
the on-board CPU and that a sensible reply is returned.
TABLE 14. Stepper Motor Controller Specifications
Item Description
Model Number VME8-8
Manufacturer Oregon Microsystems
Input Power +5 Volts @ 3 Amps (max.)
Connections via VMEbus P2 connector.
Dimensions 1 slot x 6U
Operating Temperature 0° to 50° C
Humidity 0% to 90% non-condensing
Page view 23