Motorola MVME167 User Manual Page 18

  • Download
  • Add to my manuals
  • Print
  • Page
    / 56
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 17
Time Bus Interface Card
18 of 56 ICD-13/05 ICD 13—Standard Controller
3. Switch on the enclosure power. The displays may initially show a random number,
but should immediately change to all segments on for about a second, then start
counting the time from 00:00:00.
Note that the decimal points on the displays are used to indicate if time is available
from an external source — the decimals are lit to indicate that the card is freewheel-
ing. If the card is a bc637GPS unit and the satellite receiver is plugged in and can see
the sky, there will be a delay of a few minutes while the receiver picks up the satel-
lites, but eventually the display will change to show the current time (not necessarily
local time though) and the decimal points will be extinguished.
4. If using the bc637GPS unit, install the antenna cable into J4.
5. Check that the card’s VME interface works.
167-Bug>MD FFFF4000:10
FFFF4000 FEF4 F350 XXXX XXXX FFFF FFFF 0070 01HH
FFFF4010 MMSS XXXX XXXX 00FF FFFF FFFF FFFF FFF0
If the VxWorks PROMs are in the SBC, use:
-> d 0xffff4000,16
ffff4000: fef4 f350 XXXX XXXX ffff ffff 0070 00HH *...P.........p..*
ffff4010: MMSS XXXX XXXX 00ff ffff ffff ffff fff0 *GE.5.P..........*
value = 21 = 0x15
TABLE 9. bc635VME Switch Settings
Switch Setting Type Switch Setting Type
SW1-1 On A6 SW2-1 Off A14
SW1-2 On A7 SW2-2 On A15
SW1-3 On A8 SW2-3 On Bus Type
SW1-4 On A9 SW2-4 On Bus Type
SW1-5 On A10
SW1-6 On A11
SW1-7 On A12
SW1-8 On A13
TABLE 10. bc635VME Jumper Settings
Jumper Setting Type
JP1 3-4 Modulated IRIG-B Timecode
JP2 1-2 Single Ended GPS 1PPS input
JP3 1-2 GPS Receiver Type
JP4 3-4, 5-6 Auxiliary RS422 Output
JP5 1-2 RS422 Input Termination