Protect Your Installation
Lightning Protection Zones
When the ODU is installed on a mast, tower or wall, it may be in one of two possible lightning
protection zones:
• Zone A: In this zone a direct lighting strike is possible. Do not mount the ODU in this zone.
• Zone B: In this zone, direct EMD (Lightning) effects are still possible, but mounting in this
zone significantly reduces the possibility of a direct strike. Mount the ODU in this zone.
Zone AZone A
Recommended
NOT Recommended
Zone BZone B
Zone A
Finial
Recommended
Zone B
The following protection requirements are mandatory:
• The ODU must be earthed
• Screened CAT 5e cable must be used
• Surge arrestor of type PTP-LPU must be installed at building entry
• There must be an earth connection at building entry
More information:
PTP 300 Series User Guide
or PTP 500 Series User Guide
Section: “Lightning Protection”