Testing and Fault Finding (Troubleshooting)
Perform troubleshooting (fault finding) procedures either on a newly installed link, or on an
operational link if communication is lost.
When the link end hardware (PIDU, LPU, ODU and cabling) has been installed, start it by following
this procedure:
Step 1: Connect the RJ45 from the ODU (or LPU if fitted) to the PIDU and apply mains or
battery power to the PIDU. The green Power LED should illuminate continuously.
Step 2: After 30 seconds, the yellow Ethernet LED should be observed starting with 10 slow
flashes.
Step 3: Connect the RJ45 from the LAN port of the PIDU to the network. The yellow
Ethernet LED should blink randomly as traffic passes through.
If the Power and Ethernet LEDs do not illuminate correctly, test the link end as described in this
flowchart (references such as (*1) are to the tests on the following pages):
Start
Is the green
power LED
on solid?
Is the power
LED
flashing?
Did the
Ethernet
LED flash 10
times?
Is Ethernet
activity now
normal?
Is Ethernet
connection
1000 BaseT?
No
(*1) Power LED
is Off
(*2) Power LED
Flashes
No
Yes
Yes
(*3) Ethernet LED
did not Flash 10
Times
No
Yes
Yes
No
Is there any
Ethernet
activity?
(*5) Irregular
Ethernet
Activity
(*4) No
Ethernet
Activit
y
No
Yes
(*6) Connection is
not 1000 BaseT
(*7) Test RJ45
Resistance
Yes
No