Mast, Tower or Building Installation
Step 2: Offer the ODU (with pre-fitted mounting bracket) to the bracket strap and affix using
the captive M8 bolt. Tighten to ensure the assembly grips, but can be adjusted on the pole.
Step 3: Adjust the elevation and azimuth of the unit before tightening to the required torque
settings of 14 Nm (11 lbft) for both bolts.
CAUTION: Attach the free end of one earth bonding lead (large tag M10) to the tower metal
work. On no account must this be attached to the mounting bracket bolts.
More information:
PTP 300 Series User Guide
or PTP 500 Series User Guide
Section: “Mounting the ODUs”
WARNING: A cable measuring card must NEVER be used at the ODU end connected to
power from the PIDU. It must only be used at the bottom of the mast with a multimeter.
This is because the PIDU voltage exceeds the limit allowed in some countries for safe
handling in wet conditions and therefore may create a safety hazard.