GX2-LM1000E* Installation and Operation Manual
Appendix C
Status Reporting
This appendix provides information on status reporting messages for the Element Management
System and shelf display. The event and display messages on the GX2-LM1000E* are listed in
Table C-1.
Table C-1
Event/Alarm messages for the GX2-LM1000E* 1310 nm transmitter
EMS Event Message SDU Display
Message
Status
LED
Event
Optical Power Major
Alarm
Optical Power Alarm Red Based on laser diode back detector current, optical
power is 10% less or 10% more than the factory
setpoint.
Optical Power No Alarm None Green Optical power returns within specification.
RF Input Level Major
Alarm
RF Input Level Alarm Red The total power of the RF drive level at the laser
diode is +14.5 dBm or greater.
RF Input Level Minor
Alarm
RF Input Level Alarm Yellow The total power of the RF drive level at the laser
diode is -10.5 dBm or less.
RF Input Level No
Alarm
None Green The total power of the RF drive level at the laser
diode returns within specification.
RF Overload Major
Alarm
RF Overload Alarm Red The total power of the RF drive level at the laser
diode is +16.0 dBm or greater. Module operation is
stopped.
RF Overload No Alarm None Green RF drive level at the laser diode returns below
overload condition.
OMI Offset Major Alarm OMI Offset Alarm Red RF drive level at the laser diode is 2 dB less or
2 dB more than the OMI Offset Control setpoint.
This is only active in Preset or Set mode.
OMI Offset Minor Alarm OMI Offset Alarm Yellow RF drive level at the laser diode is 0.5 dB less or
0.5 dB more than from the OMI Offset Control
setpoint. This is only active in Preset or Set mode.
OMI Offset No Alarm None Green RF drive level at the laser diode returns within
specification from the OMI Offset Control setpoint.
Module Temperature
Major Alarm
Module Temperature
Alarm
Red Internal module temperature is less than -20°C or
greater than +80°C.
Module Temperature
Minor Alarm
Module Temperature
Alarm
Yellow Internal module temperature is less than -15°C or
greater than +75°C.
Module Temperature
No Alarm
None Green Module temperature returns within specification