GX2-LM1000E* Installation and Operation Manual
Section 5
Troubleshooting
This section provides troubleshooting procedures for the GX2-LM1000E*. You can use the
procedures to correct minor problems or better define the malfunction. If the error condition
cannot be corrected, contact the TRC at 1-888-944-HELP (1-888-944-4357). Before you call,
record the input signal levels, optical output power, operating mode(s), and ambient
temperature. This information is most useful to the TRC and repair facility in troubleshooting
and repairing your GX2-LM1000E*.
The GX2-LM1000E* is a self-contained unit; therefore, when a problem is diagnosed within the
module, the entire GX2-LM1000E* must be returned for repair. See Section 1, “Introduction” for
information on equipment return.
Using the Status LED
Table 5-1 lists the troubleshooting checks you can perform using the STATUS LED only. It is
assumed that an SDU, network management system, or local access port are not available. If
these additional options are available, this table can be used in conjunction with Table 5-2.
To use Table 5-1, identify the symptom and then perform the checks in the order listed under
that symptom. For example:
If the front-panel
STATUS LED is yellow, indicating a minor alarm, go to the yellow column.
Find
c and perform that check (Verify SC/APC connector . . .).
Continue performing all checks in the yellow column, in the order given, to help identify the
cause of the minor alarm and if possible, fix the problem.
Table 5-1
Troubleshooting using the status LED only
Symptom
Status LED Indication
Flashing
Red
Red Yellow Not Lit
Poor RF
Response
Corrective Action
c
Microprocessor boot up failure. Reseat the
GX2-LM1000E* in the GX2-HSG* slot or in a
known good slot. If still flashing red, return the
GX2-LM1000E* for repair.
c
Check the STATUS LEDs on other GX2 application
modules in the GX2-HSG*. If they are not lit, verify
that AC power is applied to the system.
c
Check the STATUS LEDs on other GX2 application
modules in the GX2-HSG*. If they are also red, a
possible GX2 system-powering problem may exist.
Perform the following checks before contacting
the TRC.