Unpacking the GX2-LM1000E*
1 Unpack the GX2-LM1000E* and inspect it for damage. If damaged, set it aside in its
original packing material and contact the Motorola Customer Service department for
further instructions. See Section 1, “Introduction.”
2 Record the model number, serial number, and related information for future reference. This
information is on a label on the side of the module.
Installing the RF Interface Connectors
The GX2-HSG* is unique in that it enables you to install the GX2-LM1000E* in any application
module slot. To accommodate this feature, you need to install the RF interface connectors
provided with the GX2-LM1000E*.
To install the two RF G-to-F connectors on the rear of the GX2-HSG*:
1 Locate the plate containing the two G- to F-type connectors and the two mounting screws
included in the GX2-LM1000E* shipping carton.
2 Identify the slot that the GX2-LM1000E* will occupy in the GX2-HSG*.
3 Hold the connector plate so that the F side of the G- to F-type connectors face outward and
the tabs are in the up position.
4 Insert the tabs on the mounting plate into the slots on the rear of the GX2-HSG* that
correspond to the location of the GX2-LM1000E*.
5 Secure the plate with the two screws provided.
Figure 3-1 illustrates the RF connector plate and its correct position on the rear of the
GX2-HSG*:
Figure 3-1
Installing the RF interface connectors on the rear of the GX2-HSG*