Motorola LM100 Operations Instructions Page 52

  • Download
  • Add to my manuals
  • Print
  • Page
    / 61
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 51
Troubleshooting 5-7
GX2-LM1000E* Installation and Operation Manual
Alarm
Conditions
Status LED
Indication
Reported
Value
Corrective Action
Laser Data NVM
CRC-major alarm
Red The GX2-LM1000E* defaults to a laser protection
mode— a laser bias of 50 mA, an attenuator setting
of 7.5 dB, and Manual Mode only operation. The
GX2-LM1000E* continues to operate with these
settings. Contact the TRC.
Alarm Limit NVM
CRC-major alarm
Red Alarm checking is automatically shut off. The GX2-
LM1000E* continues to operate. Contact the TRC.
Boot status-major
alarm
Red The preferred firmware boot bank is corrupt. The
alternate firmware boot bank will be utilized. The
GX2-LM1000E* continues to operate using alternate
firmware. Contact the TRC.
Flash status-major
alarm
Red The Flash programming procedure has failed. The
GX2-LM1000E* continues to operate with the
currently loaded version of firmware. Contact the
TRC.
Hardware-major
alarm
Red The laser bias control loop window has been
exceeded. To protect the laser, the laser bias is
automatically set to 50 mA. The GX2-LM1000E*
continues to operate with this setting. Cycle the
optical output power using the SDU, network
management system, or local access port to clear
the alarm. If the problem persists, contact the TRC.