4-4 Operation
GX2-LM1000E* Installation and Operation Manual
If the RF drive level to the laser is OFF when you turn the optical output power OFF, it will
remain off when the optical output power is restored.
Quick Swap
The quick-swap feature reduces down time by eliminating the need to manually reconfigure
replacement application modules of the same type in the same housing slot. Replacement
modules are recognized and updated with settings pre-stored by the GX2-CM100B control
module. This feature is particularly useful in the event of module failure.
The following module-specific parameters are contained in the quick-swap message sent from
the GX2-CM100B to the GX2-LM1000E*:
Module Alias
RF input on/off control setting
Optical output on/off control setting
Primary operating mode
Secondary operating mode
CW/Video mode offset
Laser RF input level control (OMI offset)
RF attenuator setting
The GX2-LM1000E* reads the quick-swap message from the GX2-CM100B, automatically
resets, and re-initializes itself to the same configuration as contained in the message. If the
GX2-LM1000E* is in Preset mode, it uses the factory default optimum OMI setting to determine
the RF level at the laser. If the GX2-LM1000E* is in Set mode, the laser RF input level control
(OMI offset) determines the RF level at the laser. If the GX2-LM1000E* is in Manual mode, the
attenuator setting determines the RF level at the laser. If the quick-swap message intended for
the GX2-LM1000E* is sent to another type of module, the command is rejected and the module
information is not replaced.
Instructions for selecting and implementing the quick-swap mode are provided in the
GX2-CM100B Control Module Installation and Operation Manual.