16 AP6562 Access Point
To use only the extension arm:
1. Using four #10/32 lag bolts, attach the extension arm at the desired mounting location.
2. Using a torque wrench or a ratchet and a 10mm socket, or an adjustable wrench, attach the mounting
extension arm to the access point with four M6 hex flange screws. Tighten the hex flange screws to 60
inch pounds (lbf-in).
To use the extension arm with the mounting hardware kit:
1. With the open slot connections facing down, attach the angle adapter bracket section at the desired
mounting location using four #10/32 lag bolts.
2. Complete the steps for assembling and positioning the angle adapter bracket and access point bracket
sections as outlined above (see
Vertical Pole Mount on page 12).
3. Attach the extension arm to the access point bracket section of the assembled mounting bracket already
in position using four M6 hex flange screws. Tighten the hex flange screws to 60 inch pounds (lbf-in).
4. Using a torque wrench or a ratchet and a 10mm socket, or an adjustable wrench, attach the extension arm
to the access point with four M6 hex flange screws. Tighten the hex flange screws to 60 inch pounds
(lbf-in).
CAUTION If not using a 802.3at capable controller to power the AP6562, ensure
only the AP6562’s designated outdoor power supply
(AP-PSBIAS-7161-US or AP-PSBIAS-7161-WW) is used to supply
power to the access point. Using an incorrectly rated power supply
could damage the unit and void the product warranty. Do not actually
connect to the power source until the cabling portion of the
installation is complete.