Motorola AP6562 Installation Guide Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 48
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
Installation Guide 15
2.3.5 Wall Mounted Installation
For wall mounted installations, use only the access point bracket and if required the angle adapter bracket. The
access point can also be installed using the sheet metal tab on the top of the enclosure.
1. With the open slot connections facing down, attach the angle adapter bracket section at the desired
mounting location using four #10/32 lag bolts.
2. Using a torque wrench or a ratchet and a 10mm socket, or an adjustable wrench, attach (but don’t tighten)
the access point bracket section to the AP6562 with four M6 hex flange screws and insert two M6 hex
flange screws into the bottom holes on the sides of the access point bracket section.
3. Insert the two M6 hex flange screws in the bottom holes on the sides of the access point bracket section
into the open slot connections on the bottom of the angle adapter bracket section.
4. Rotate the access point bracket section upward and align the top holes on the sides with the top holes on
the angle adapter bracket section. Insert two M6 hex flange screws into the top holes on the angle
adapter bracket section.
5. Use a torque wrench or a ratchet and a 10mm socket, or an adjustable wrench, to finish attaching the
angle adapter bracket section to the access point bracket section with the four M6 hex flange screws in
the open slot connections and the top holes on the angle adapter bracket section. Do not tighten the
screws until all rotation and tilt adjustments are complete.
6. To adjust the position of the access point, rotate the access point bracket section (plus or minus 15
degrees) and tilt the angle adapter bracket section (up to 45 degrees).
7. Tighten all hex flange screws to 60 inch pounds (lbf-in).
8. If required, install and attach a Kensington security cable (customer supplied) to the unit’s lock port.
9. Attach an Ethernet cable from the access point to a controller with an 802.3at-compatible power source
or use the designated outdoor rated power supply (AP-PSBIAS-7161-US or AP-PSBIAS-7161-WW) to
supply power to the AP6562 (once fully cabled).
10. Verify the unit has power by observing that the LEDs are lit or flashing.
NOTE The U-bolt and band clamps are not included in the mounting bracket kit.
NOTE The lag bolts are not included in the mounting bracket kit.
Page view 14