Motorola MOSCAD 68P02958C00-B User Manual Page 280

  • Download
  • Add to my manuals
  • Print
  • Page
    / 474
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 279
APPENDIX B:
Remote ToolBox Modem Setup
B-9
UDS V.3225
Modem UDS V.3225
UDS V.3225UDS V.3225
UDS V.3225
Type External
Model V.3225 LCD MINI SA
Version
Configuration (9600 Baud)
at&v
ACTIVE PROFILE
S00:001 S01:000 S02:043 S03:013 S04:010 S05:008 S06:002 S07:030
S08:002 S09:006 S10:014 S12:050 S14:8AH S16:00H S18:000 S21:84H
S22:46H S23:00H S25:005 S26:000 S27:08H S28:015 S29:000 S32:06H
S34:00H S52:000 S53:00H S54:01H S57:00H S58:000 S59:005 S60:41H
S61:1EH S62:000 S63:255 S67:005 S69:005 S70:001 S71:00H S72:00H
S78:030 S79:035
OK
Modem Settings
Instructions to load Factory Option Set #2 (Asynchronous Dial-up without MNP)
(Settings are made from front panel of modem.)
[V.32 9600 TALK] Press NO
[DIAL STORED NUMBER ?] Press NO
[DISPLAY STATUS ?] Press NO
[SELECT TEST ?] Press NO
[MODIFY CONFIGURATION ?] Press YES
[CHANGE MODEM PARAMETERS ?] Press NO
[CHANGE MNP PARAMETERS ?] Press NO
[CHANGE DTE PARAMETERS ?] Press NO
[CHANGE TEST PARAMETERS ?] Press NO
[CHANGE DIAL LINE PARAMETERS ?] Press NO
[CHANGE SPEAKER OPERATION ?] Press NO
[LOAD OR STORE OPTION SET ?] Press YES
[LOAD FACTORY OPTION SET ?] Press YES
[ARE YOU SURE ?] Press YES
[LOAD FACTORY OPTION SET #1 ?] Press NO
[LOAD FACTORY OPTION SET #2 ?] Press YES
(Brief message will be displayed)
[STORE PRESENT OPTIONS ?] Press YES
[ARE YOU SURE ?] Press YES
(Brief message will be displayed)
[MODIFY CONFIGURATION ?] Press TALK/DATA
Page view 279
1 ... 279 280 281 ... 474

Comments to this Manuals

No comments