Diagnostics 4-13
DCT6200\DCT6208 Installation Manual
MODE
The values for the MODE display on the OSD are:
Table 4-13
MODE values - OSD
Value Description
ANALOG IB Contains an Analog channel
64 QAM IB Contains a Digital channel with a modulation mode of 64 QAM
256 QAM IB Contains a Digital channel with a modulation mode of 256 QAM
CARRIER LOCK
Indicates if the IB receiver is locked to the carrier:
Table 4-14
In-Band CARRIER LOCK - OSD and LED
OSD Display LED Display Definition
YES L Carrier locked
NO U Carrier unlocked
DATA
The IB data indicates if data is being carried on the IB stream. The indicators cover all packet
processors regardless of which stream they are monitoring.
Table 4-15
In-Band DATA indicators – OSD and LED
OSD Display LED Indicator Definition
YES on IB Data detected within last 5 seconds
NO off IB Data not detected within last 5 seconds