Downloading a configuration
The HP E2480A is shipped with all reconstruction disabled. This
preprocessor configuration provides accurate analysis when A[19:23],
FC[0:2], SIZ0, SIZ1, DSACK0, and DSAK1 are valid. If your target system is
configured differently, you must configure the preprocessor to match your
target system configuration.
To configure the preprocessor, the HP E2480A must be connected to an
HP E3458A Processor Probe. The processor probe must be connected to a
computer via LAN or RS-232-C. The HP E2480A preprocessor may be
configured from either an HP approved debugger or the HP 16505A
Prototype Analyzer. For a list of HP approved debugger vendors, contact
your HP Sales and Service office.
Configuring With a Debugger
Using a debugger, there are two methods of configuration. The first method
requires values to be manually written into SIM/SCIM registers MCR, PEPAR,
CSPAR0, CSPAR1, and the CSBARx and CSORx of all chip selects being
used. The second method requires code to be loaded into the target,
performing a "reset" and "run", then performing a "break" after the SIM/SCIM
registers have been configured. In either case, once the SIM/SCIM registers
are configured, telnet to the processor probe (HP E3458A) and perform
"sync sim" and "pp load". This will place information needed by the
preprocessor for configuration in the preprocessor non-volatile memory.
Configuring With the HP 16505A Prototype Analyzer
Using the HP 16505A Prototype Analyzer, move the uP run control icon into
the workspace, click the right mouse button and select "Start Session"’. A "uP
run control" window should appear. In the "Processor Probe LAN Name"
field, place the LAN name of the HP E3458A connected to the target of
interest and click "start session".
When a connection is established, an "Information" window should appear
indicating connection success. Click on "OK". Another window, "run control"
should also appear. Under the "Window" pull-down menu, select
"Configuration". Two windows should appear, "Configuration" and
"Error/status log".
Using the "Configuration" window, there are two methods of preprocessor
configuration. The first method requires values to be manually written into
SIM/SCIM register fields MCR, PEPAR, CSPAR0, CSPAR1, and the CSBARx
Chapter 2: Hooking up Your System
Downloading a configuration