MPC564EVB Users Manual B-3
Troubleshooting Network Problems
fail, and probably other severe network problems. Make certain the client IP address is unique for
the board.
Check for proper insertion or connection of the network cable. Is the status LED lit indicating that
network traffic is present?
Check for proper configuration and operation of the TFTP server. Most Unix workstations can
execute a command named tftp which can be used to connect to the TFTP server as well. Is the
default TFTP root directory present and readable?
If ICMP_DESTINATION_UNREACHABLE or similar ICMP message appears, then a serious
error has occurred. Reset the board, and wait one minute for the TFTP server to time out and
terminate any open connections. Verify that the IP addresses for the server and gateway are correct.
Also verify that a TFTP server is running on the server.