P460/P360 MemoryScannersProduct Reference Guide
ixAbout This ManualIntroductionThe P460/P360 Memory Scanner Product Reference Guide provides general instructions for setup, operation, troubleshootin
5-41Parameter MenusEAN Zero ExtendIf this parameter is enabled, five leading zeros are added to decoded EAN-8 symbols to make them compatible in forma
5-42P460/P360 Memory Scanners Product Reference GuideConvert EAN-8 to EAN-13 TypeWhen EAN Zero Extend is enabled, this parameter gives you the option
5-43Parameter MenusUPC/EAN Coupon CodeWhen this parameter is enabled, the Phaser decodes UPC-A, UPC-A with 2 supplemental characters, UPC-A with 5 sup
5-44P460/P360 Memory Scanners Product Reference GuideEnable/Disable Code 128Scan the appropriate bar code below to enable or disable Code 128.ENABLE C
5-45Parameter MenusEnable/Disable UCC/EAN-128Scan the appropriate bar code below to enable or disable UCC/EAN-128. (See Appendix A, Bar Code Informati
5-46P460/P360 Memory Scanners Product Reference GuideEnable/Disable ISBT 128 (2D Scanner only)To enable or disable ISBT 128, scan the appropriate bar
5-47Parameter MenusEnable/Disable Code 39Scan the appropriate bar code below to enable or disable Code 39.ENABLE CODE 39DISABLE CODE 39
5-48P460/P360 Memory Scanners Product Reference GuideEnable/Disable Trioptic Code 39Trioptic Code 39 symbols always contain six characters. Trioptic C
5-49Parameter MenusSet Lengths for Code 39Lengths for Code 39 may be set for any length, one or two discrete lengths, or lengths within a specific ran
5-50P460/P360 Memory Scanners Product Reference GuideSet Lengths for Code 39 (Continued)Length Within Range - This option allows you to decode a code
xP460/P360 Memory Scanners Product Reference Guide" lists of alternatives" lists of required steps that are not necessarily sequential!Seque
5-51Parameter MenusCode 39 Check Digit VerificationWhen enabled, this parameter checks the integrity of a Code 39 symbol to ensure it complies with sp
5-52P460/P360 Memory Scanners Product Reference GuideTransmit Code 39 Check DigitScan the appropriate bar code below to transmit the data with or with
5-53Parameter MenusEnable/Disable Code 39 Full ASCIIScan the appropriate bar code below to enable or disable Code 39 Full ASCII.When enabled, the ASCI
5-54P460/P360 Memory Scanners Product Reference GuideConvert Code 39 to Code 32Scan the appropriate bar code below to enable or disable converting Cod
5-55Parameter MenusCode 32 PrefixScan the appropriate bar code below to enable or disable the prefix character “A” to all Code 32 bar codes.Note:Conve
5-56P460/P360 Memory Scanners Product Reference GuideEnable/Disable Code 93Scan the appropriate bar code below to enable or disable Code 93.ENABLE COD
5-57Parameter MenusSet Lengths for Code 93Lengths for Code 93 may be set for any length, one or two discrete lengths, or lengths within a specific ran
5-58P460/P360 Memory Scanners Product Reference GuideSet Lengths for Code 93 (Continued)Length Within Range - This option allows you to decode a code
5-59Parameter MenusEnable/Disable Interleaved 2 of 5Scan the appropriate bar code below to enable or disable Interleaved 2 of 5.ENABLE INTERLEAVED 2 O
5-60P460/P360 Memory Scanners Product Reference GuideSet Lengths for Interleaved 2 of 5 Lengths for I 2 of 5 may be set for any length, one or two dis
xiAbout This ManualSymbol Support CenterFor service information, warranty information or technical assistance contact or call the Symbol Support Cente
5-61Parameter MenusSet Lengths for Interleaved 2 of 5 (Continued)Length Within Range - This option allows you to decode a code type within a specified
5-62P460/P360 Memory Scanners Product Reference GuideI 2 of 5 Check Digit VerificationWhen enabled, this parameter checks the integrity of an I 2 of 5
5-63Parameter MenusTransmit I 2 of 5 Check DigitScan the appropriate bar code below to transmit the data with or without the check digit.TRANSMIT I 2
5-64P460/P360 Memory Scanners Product Reference GuideConvert I 2 of 5 to EAN-13This parameter converts a 14 character I 2 of 5 code into EAN-13, and t
5-65Parameter MenusEnable/Disable Discrete 2 of 5Scan the appropriate bar code below to enable or disable Discrete 2 of 5.ENABLE DISCRETE 2 OF 5DISABL
5-66P460/P360 Memory Scanners Product Reference GuideSet Lengths for Discrete 2 of 5 Lengths for D 2 of 5 may be set for any length, one or two discre
5-67Parameter MenusSet Lengths for Discrete 2 of 5 (Continued)Length Within Range - This option allows you to decode a code type within a specified ra
5-68P460/P360 Memory Scanners Product Reference GuideEnable/Disable CodabarScan the appropriate bar code below to enable or disable Codabar.ENABLE COD
5-69Parameter MenusSet Lengths for CodabarLengths for Codabar may be set for any length, one or two discrete lengths, or lengths within a specific ran
5-70P460/P360 Memory Scanners Product Reference GuideSet Lengths for Codabar (Continued)Length Within Range - This option allows you to decode a code
xiiP460/P360 Memory Scanners Product Reference GuideFinlandOy Symbol TechnologiesKaupintie 8 A 6FIN-00440 Helsinki, Finland9 5407 580 (Inside Finland)
5-71Parameter MenusCLSI EditingIf enabled, this parameter strips the start and stop characters and inserts a space after the first, fifth, and tenth c
5-72P460/P360 Memory Scanners Product Reference GuideNOTIS EditingIf enabled, this parameter strips the start and stop characters from a decoded Codab
5-73Parameter MenusEnable/Disable MSI PlesseyScan the appropriate bar code below to enable or disable MSI Plessey.ENABLE MSI PLESSEYDISABLE MSI PLESSE
5-74P460/P360 Memory Scanners Product Reference GuideSet Lengths for MSI Plessey Lengths for MSI Plessey may be set for any length, one or two discret
5-75Parameter MenusSet Lengths for MSI Plessey (Continued)Length Within Range - This option allows you to decode a code type within a specified range.
5-76P460/P360 Memory Scanners Product Reference GuideMSI Plessey Check DigitsThese check digits at the end of the bar code verify the integrity of the
5-77Parameter MenusTransmit MSI Plessey Check DigitScan the appropriate bar code below to transmit the data with or without the check digit.TRANSMIT M
5-78P460/P360 Memory Scanners Product Reference GuideMSI Plessey Check Digit AlgorithmWhen the two MSI Plessey check digits option is selected, an add
5-79Parameter MenusEnable/Disable PDF417Scan a bar code below to enable or disable PDF417 scanning.Note:PDF417 parameters are available only on the 2D
5-80P460/P360 Memory Scanners Product Reference GuidePDF417 Scanning ModeThis parameter allows you to select one of the following scanning mode option
xiiiAbout This ManualIf you purchased your Symbol product from a Symbol Business Partner, contact that Business Partner for service.WarrantySymbol Tec
5-81Parameter Menus3. If you make an error, or wish to change your selection, scan CANCEL.Raster Height (Default 15)Raster Expansion Speed (Default 11
5-82P460/P360 Memory Scanners Product Reference GuideProgrammable Raster Height And Raster Expansion Speed (Continued)1234567890Cancel
5-83Parameter MenusAiming ModeThis parameter allows you to select either an aiming dot or slab raster for aiming.Select the aiming mode.Note:Aiming mo
5-84P460/P360 Memory Scanners Product Reference GuideEnable/Disable MicroPDFScan a bar code below to enable or disable MicroPDF417 scanning.Enable MIC
5-85Parameter MenusCode 128 EmulationWhen this parameter is enabled, the scanner transmits data from certain MicroPDF417 symbols as if it was encoded
5-86P460/P360 Memory Scanners Product Reference GuideUCC/EAN-128 EmulationCertain MicroPDF417 symbols can be “linked” with a linear symbol during tran
5-87Parameter MenusMacro PDF Features This section discusses programmable Macro PDF features fully supported by the scanner. Macro PDF is a special fe
5-88P460/P360 Memory Scanners Product Reference GuideMacro PDF Transmit / Decode Mode SymbolsSelect only one of the four options below for handling th
5-89Parameter MenusMacro PDF Transmit / Decode Mode Symbols (Continued)Buffer All Symbols / Transmit When CompleteBuffer Scans Out Of Order/Transmit S
5-90P460/P360 Memory Scanners Product Reference GuideTransmit Symbols in Codeword FormatEnabling this activates transmission of each PDF symbol as dir
xivP460/P360 Memory Scanners Product Reference GuideWarranty Coverage and ProcedureDuring the warranty period, Symbol will repair or replace defective
5-91Parameter MenusTransmit Unknown CodewordsThis enables using the output codeword format for transmitting any non-GLI or non-macro PDF codeword. If
5-92P460/P360 Memory Scanners Product Reference GuideEscape CharactersThis enables the backslash (\) character as an Escape character for systems that
5-93Parameter MenusDelete Character Set ECIsThis parameter enables the scanner to delete any escape sequences representing Character Set ECIs (also kn
5-94P460/P360 Memory Scanners Product Reference GuideECI DecoderThis parameter enables the scanner to interpret any Extended Channel Interpretations (
5-95Parameter MenusTransmit Macro PDF User-Selected FieldsWhen enabled, the following parameters cause transmission of the specified field in subseque
5-96P460/P360 Memory Scanners Product Reference GuideTransmit Block CountTransmit Block Count activates transmission of the block count field. The fie
5-97Parameter MenusTransmit SenderTransmit Sender activates transmission of the sender field. The field character tag is \923\003. For example, the fi
5-98P460/P360 Memory Scanners Product Reference GuideTransmit ChecksumTransmit Checksum activates transmission of the checksum field. The field charac
5-99Parameter MenusTransmit Macro PDF Control HeaderTransmit Macro PDF Control Header activates transmission of the control header, which contains the
5-100P460/P360 Memory Scanners Product Reference GuideFlush Macro BufferThis flushes the buffer of all decoded Macro PDF data stored to that point, tr
1-1Chapter 1 The Phaser Series ScannerIntroductionThe P460/P360 Memory Scanners bring new flexibility and economy to data capture and data management
5-101Parameter MenusSecurity OptionsLinear Code Type Security LevelsThe Phaser offers four levels of decode security for linear code types (e.g., Code
5-102P460/P360 Memory Scanners Product Reference GuideLinear Code Type Security Level (Continued)Linear Security Level 3Code types other than the foll
5-103Parameter MenusBi-directional RedundancyThis parameter is only valid when a Linear Code Type Security Level (see page 5-101) is enabled. When thi
5-104P460/P360 Memory Scanners Product Reference GuideUPC/EAN Security LevelThe Phaser offers four levels of decode security for UPC/EAN bar codes. In
5-105Parameter MenusUPC/EAN Security Level (Continued)UPC/EAN Security Level 2If you are experiencing mis-decodes of poorly printed bar codes, and the
5-106P460/P360 Memory Scanners Product Reference GuideRS-232C ParametersBaud RateBaud rate is the number of bits of data transmitted per second. The s
5-107Parameter MenusBaud Rate (Continued)BAUD RATE 4800BAUD RATE 9600BAUD RATE 19200BAUD RATE 38400
5-108P460/P360 Memory Scanners Product Reference GuideParityA parity check bit is the most significant bit of each ASCII coded character. Select the p
5-109Parameter MenusSelect SPACE parity and the parity bit is always 0.SPACEIf no parity is required, select NONE.NONECheck Receive ErrorsSelect wheth
5-110P460/P360 Memory Scanners Product Reference GuideHardware HandshakingThe data interface consists of an RS-232C port. The port has been designed t
1-2P460/P360 Memory Scanners Product Reference GuideThe CradleThe PL 460 and PL 360 Cradles act as a:!stand!communication interface with the host!batt
5-111Parameter MenusHardware Handshaking (Continued)Scan the bar code below if no Hardware Handshaking is desired.NONEScan the bar code below to selec
5-112P460/P360 Memory Scanners Product Reference Guideasserted within two seconds (default), the scanner issues an error indication and discards the d
5-113Parameter MenusSoftware Handshaking (Continued)ACK/NAKWhen this option is selected, after transmitting data, the cradle expects either an ACK, Ac
5-114P460/P360 Memory Scanners Product Reference GuideSoftware Handshaking (Continued)XON/XOFFAn XOFF, Transmit Off, character turns the scanner trans
5-115Parameter MenusRTS Line StateNote:This only applies to the scanner in corded mode. It has no affect when uploading data through the cradle.Scan t
5-116P460/P360 Memory Scanners Product Reference GuideStop Bit SelectThe stop bit(s) at the end of each transmitted character marks the end of transmi
5-117Parameter MenusBeep on <BEL>When this parameter is enabled, the scanner beeps when a <BEL> character is detected on the RS-232C seria
5-118P460/P360 Memory Scanners Product Reference GuideMCL-Net ParametersMCL-Net Baud RateBaud rate is the number of bits of data transmitted per secon
5-119Parameter MenusMCL-Net Baud Rate (Continued)BAUD RATE 4800BAUD RATE 9600BAUD RATE 19200BAUD RATE 38400
5-120P460/P360 Memory Scanners Product Reference GuideMCL-Net Hex Addressing ModeScan the appropriate bar code below to set the MCL-Net Hex addressing
1-3The Phaser Series ScannerThere are two versions of the Cradle:!PL 460 Cradle: batch retail version!PL 360 Cradle: batch industrial version.Unless o
5-121Parameter MenusMCL-Net Transmit RetriesScan the following barcode, followed by 2 digits from the numeric barcode section (starting on page 5-122)
5-122P460/P360 Memory Scanners Product Reference GuideNumeric Bar CodesFor parameters requiring specific numeric values, scan the appropriately number
5-123Parameter MenusNumeric Bar Codes (Continued)56789
5-124P460/P360 Memory Scanners Product Reference GuideNumeric Bar Codes (Continued)CancelIf you make an error, or wish to change your selection, scan
A-1Appendix ABar Code InformationUCC/EAN-128UCC/EAN-128 is a convention for printing data fields with standard Code 128 bar code symbols. UCC/EAN-128
A-2P460/P360 Memory Scanners Product Reference GuideTable A-1. Reading Standard Code128 & UCC/EAN 128Standard Code 128UCC/EAN-128 Effect and Examp
A-3Bar Code InformationAIM Code IdentifiersEach AIM Code Identifier contains the three-character string ]cm where:] = Flag Character (ASCII 93)c = Cod
A-4P460/P360 Memory Scanners Product Reference GuideThe modifier character is the sum of the applicable option values based on the following table.Tab
A-5Bar Code InformationCodabar 0 No check digit processing.1 Reader has checked check digit.3 Reader has stripped check digit before transmission.Exam
A-6P460/P360 Memory Scanners Product Reference GuideAccording to AIM standards, a UPC with supplemental bar code is transmitted in one of the followin
1-4P460/P360 Memory Scanners Product Reference Guide
A-7Bar Code InformationTable A-4. ASCII Character Set ASCIIValueFull ASCII Code 39 Encode Char.Keystroke ASCIIValueFull ASCII Code 39 Encode CharKeys
A-8P460/P360 Memory Scanners Product Reference GuideASCIIValueFull ASCII Code 39 Encode Char.Keystroke ASCIIValueFull ASCII Code 39 Encode CharKeystro
A-9Bar Code InformationASCIIValueFull ASCII Code 39 Encode Char.Keystroke ASCIIValueFull ASCII Code 39 Encode CharKeystroke1098 +B b 1113 +Q q1099 +C
A-10P460/P360 Memory Scanners Product Reference GuideALT Keys Keystroke ALT Keys Keystroke ALT Keys Keystroke2064 ALT 2 2075 ALT K 2086 ALT V2065 ALT
A-11Bar Code InformationPF Keys Keystroke PF Keys Keystroke PF Keys Keystroke4001 PF 1 4009 PF 9 4017 PF 174002 PF 2 4010 PF 10 4018 PF 184003 PF 3 40
A-12P460/P360 Memory Scanners Product Reference GuideNumericKeypadKeystroke NumericKeypadKeystroke NumericKeypadKeystroke6042 * 6049 1 6056 86043 + 60
B-1Appendix BMessages and Error CodesIntroductionThis chapter contains information on messages displayed on the scanner.MessagesThe scanner displays
B-2P460/P360 Memory Scanners Product Reference Guide
Index-1IndexAabort macro PDF Entry . . . . . . . . . . . . . . . . 5-7accessoriesoptional . . . . . . . . . . . . . . . . . . . . . . . . 4-3requi
Index-2P460/P360 Memory Scanners Product Reference GuidemacroPDF . . . . . . . . . . . . . . . . . . 5-6, 5-87delete character set ECIs . . . . . 5
P460/P360 Memory ScannersProduct Reference Guide70-37690-02Revision AJune 2001
2-1Chapter 2 Set UpIntroductionThis chapter covers the procedures for setting up the Phaser and its accessories.Unpacking Remove the scanner from its
Index-3Indexinstalling . . . . . . . . . . . . . . . . . . . . . . . . 2-1carriage return . . . . . . . . . . . . . . . . . . . . . 3-13charge sta
Index-4P460/P360 Memory Scanners Product Reference Guideescape character . . . . . . . . . . . . . . . . . . . . 5-6Exit System Setup Mode . . . .
Index-5IndexMCL-Net . . . . . . . . . . . . . . . . . . . . . 3-8, 5-121MCL-Net Baud Rate . . . . . . . . 5-8, 5-118MCL-Net Frame Timeout . . . .
Index-6P460/P360 Memory Scanners Product Reference GuideScanning Made Easy . . . . . . . . . . . . . . . . . 1-1Scanning Mode . . . . . . . . . . .
Index-7IndexVversion . . . . . . . . . . . . . . . . . . . . . . . 3-8, 3-13Wwake up . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2Yya
Index-8P460/P360 Memory Scanners Product Reference Guide
Thank you for your input—We value your comments.Tell Us What You Think...We’d like to know what you think about this Manual. Please take a moment to f
70-37690-02Revision A — June 2001Symbol Technologies, Inc. One Symbol Plaza, Holtsville N.Y. 11742-1300P460/P360 Memory Scanners Product Reference Gui
2-2 P460/P360 Memory Scanners Product Reference Guide2. Plug the modular connector on the cable into the receptacle in the bottom of the Phaser handle
2-3Set UpDisconnecting CablesTo disconnect the scanner cable:1. Power down all the devices connected to the scanner.2. Remove the cable by twisting th
2-4 P460/P360 Memory Scanners Product Reference GuideScanner Power OptionsTwo power options are available:!Battery!Power Supply (“Charging”) CableChar
2-5Set Upwhereas a scanner with a partially charged battery begins charging after approximately 15 minutes. Note that the scanner can be removed from
2-6 P460/P360 Memory Scanners Product Reference Guide3. For the scanner cable, plug the power supply cable into the power supply port on the housing o
2-7Set Up4. Plug the Synapse Interface cable into the host device.5. Connect an appropriate power supply to the power receptacle in the Synapse Interf
2-8 P460/P360 Memory Scanners Product Reference Guide
3-1Chapter 3 OperationIntroductionThis chapter covers how to use the Phaser scanner.Default ApplicationsThe Phaser is shipped from the factory with t
3-2P460/P360 Memory Scanners Product Reference GuideInitial PowerupAfter a few seconds, the System Banner is replaced by the system initialization scr
ii 2001 by Symbol Technologies, Inc. All rights reserved.No part of this publication may be reproduced or used in any form, or by any electrical or m
3-3OperationNumeric Data EntryThis inventory application also allows you to manually enter data if no bar code is present. After keying in data, press
3-4P460/P360 Memory Scanners Product Reference GuideEliminating Repetitive ScanningTo eliminate repetitive scanning of identical items, you can enter
3-5OperationTo delete stored records:1. Press the <BK> key to select a record to delete. The confirmation screen displays:2. Press Enter to dele
3-6P460/P360 Memory Scanners Product Reference GuidePressing the <BK> key causes the bar code data to be retained in memory. If this is done, an
3-7OperationThe scan and transmit screen appears as follows:In this mode, scanned bar codes are automatically transmitted to the host in real time. Al
3-8P460/P360 Memory Scanners Product Reference GuideBelow is the list of available options. Press the Up and Down arrow keys to scroll through them
3-9OperationNote:The scanner contains a backup power source to retain the time and date information for up to 24 hours after loss of battery power. If
3-10P460/P360 Memory Scanners Product Reference GuideOption Description0. Load App / File Puts the scanner into a mode to receive application download
3-11Operation2. System Code Updates the scanner operating system (Firmware). An RS232 cable is required to download a new operating system. To enter t
3-12P460/P360 Memory Scanners Product Reference GuideParameter ControlParameter Control allows you to control the scanner parameters such as Scan Para
iiiContentsAbout This ManualIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-13OperationErase FileErase File allows you to erase your scanner batch data. All batch data files must be transferred from the scanner to the host b
3-14P460/P360 Memory Scanners Product Reference GuideNote:Advanced data formatting rules created with ADF Plus are for use with the default applicatio
3-15Operation• The larger the symbol, the farther away you should hold the scanner.• Hold the scanner closer for symbols with bars that are close toge
3-16P460/P360 Memory Scanners Product Reference GuideHold at an AngleDo not hold the scanner directly over the bar code. Laser light reflecting direct
3-17OperationUPCPDF417Symbol Technologies, Inc.
3-18P460/P360 Memory Scanners Product Reference GuideP460/P360 1D Scanner Decode ZoneFigure 3-3. P460/P360 1D Scanner Decode Zone0 in.0 cm 5 in.12.
3-19OperationP460/P360 2D Scanner Decode ZoneFigure 3-4. P460/P360 2D Scanner - 2D Bar Code Decode ZoneIn.cm06.6 mil PDF6.010 mil PDF9.50In. cm
3-20P460/P360 Memory Scanners Product Reference GuideFigure 3-5. P460/P360 2D Scanner - 1D Bar Code Decode ZoneIn.cm0UPC15.020 mil20.50In. cmWi
3-21OperationKeypad OperationInstead of scanning a bar code, you can enter the bar code data using the keypad on the top of the scanner. To enter nume
3-22P460/P360 Memory Scanners Product Reference GuideTo put a decimal point (.) into numeric data, type in the numbers before the decimal point, then
ivP460/P360 Memory Scanners Product Reference GuideRS-232 Power Supply Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-23OperationTroubleshootingRefer to Appendix B, Messages and Error Codes for additional troubleshooting information.Nothing happens when you follow t
3-24P460/P360 Memory Scanners Product Reference GuideThe scanner does not decode the bar codes in the system menu section?Your scanner firmware does n
4-1Chapter 4 Maintenance And SpecificationsIntroductionThis chapter explains how to maintain your scanner and the specifications for it.Maintenance!D
4-2 P460/P360 Memory Scanners Product Reference Guide2. Remove the battery compartment cover.Figure 4-1. Removing the Battery Compartment Cover3. Sli
4-3Maintenance And SpecificationsCharge Status LED IndicationsThe LED indicator on the cradle uses flashing patterns to display the charger status, as
4-4 P460/P360 Memory Scanners Product Reference GuideTechnical SpecificationsTable 4-2. Technical Specifications for P460/P360 1D Scann erItem Descrip
4-5Maintenance And SpecificationsTable 4-3. Technical Specifications for P460/P360 2D Scann erItem DescriptionDecode Capability PDF417, MicroPDF417, U
4-6 P460/P360 Memory Scanners Product Reference GuidePin-outsCradleThe following table shows the pin-outs for both COM1 and COM2 on the cradle.Table 4
4-7Maintenance And SpecificationsScannerThe following table shows the pin-outs for the scanner.Table 4-5. Scanner Pin-outsPin Scanner1 Not Used2 Power
4-8 P460/P360 Memory Scanners Product Reference GuideBeeper IndicationsTable 4-6. Beeper Indications Beeper Sequence IndicationStandard UseShort high
vContentsPin-outs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-1Chapter 5 Parameter MenusIntroductionThis chapter has the optional parameter bar codes necessary to program the Phaser scanner.Operational Paramet
5-2P460/P360 Memory Scanners Product Reference GuideThe following table lists the defaults for all parameters. If you wish to change any option, scan
5-3Parameter MenusBeeper Volume High High 5-26Power Detect Beep Enable Enable 5-27Beep After Good Decode Enable Enable 5-28Decode OptionsTransmit “No
5-4P460/P360 Memory Scanners Product Reference GuideUPC-E1 Preamble System Character System Character 5-38Convert UPC-E to A Disable Disable 5-39Conve
5-5Parameter MenusCode 93Code 93 Disable Disable 5-56Set Length(s) for Code 93 4-55 4-55 5-57Interleaved 2 of 5Interleaved 2 of 5 Enable Enable 5-59Se
5-6P460/P360 Memory Scanners Product Reference GuideMSI Plessey Check Digits One One 5-76Transmit MSI Plessey Check DigitDisable Disable 5-77MSI Pless
5-7Parameter MenusECIDelete Character Set ECIs N/A Enable 5-93ECI Decoder N/A Enable 5-94Transmit Macro PDF User-Selected FieldTransmit File Name N/A
5-8P460/P360 Memory Scanners Product Reference GuideRS-232 Host Type Standard Standard 5-12Baud Rate 9600 9600 5-107Parity None None 5-108Check Receiv
5-9Parameter MenusSet Default ParameterScanning this bar code returns all parameters to the values listed in Table 5-1.SET ALL DEFAULTS
5-10P460/P360 Memory Scanners Product Reference GuideCommunication ProtocolThe bar codes below set the communication protocol used by the default appl
viP460/P360 Memory Scanners Product Reference GuideConvert EAN-8 to EAN-13 Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-11Parameter MenusBatch/Inventory ApplicationThis communication protocol is used when you are ready to transmit your batch records (data collected wh
5-12P460/P360 Memory Scanners Product Reference GuideHost TypeRS-232 Host TypesMost RS-232C hosts work fine with the default settings, however, three
5-13Parameter MenusScan the appropriate bar code below to select an RS-232C Host Interface.STANDARD RS-232CICL RS-232CNIXDORF RS-232C Mode ANIXDORF RS
5-14P460/P360 Memory Scanners Product Reference GuideCode ID Characters for RS232C Host TypesSelecting the ICL, Fujitsu, or Nixdorf RS-232C host inter
5-15Parameter MenusSleep TimeScan the bar code below to select how long the scanner will “stay awake” (not power down) in seconds after a trigger pull
5-16P460/P360 Memory Scanners Product Reference GuideDate SeparatorScan the appropriate bar code below to select which separator to use when displayin
5-17Parameter MenusHour TypeScan the appropriate bar code below to select how to display the hour and transmit it to the host device. Choose 12 HOUR (
5-18P460/P360 Memory Scanners Product Reference GuideDecimal SeparatorScan the appropriate bar code below to select what separator to display when you
5-19Parameter MenusDate FormatScan the appropriate bar code below to select how to format the date when it is displayed and transmitted to the host de
5-20P460/P360 Memory Scanners Product Reference GuideKey ClickScan the appropriate bar code below to select whether the keypad click is enabled or not
viiContentsEscape Characters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-92Delet
5-21Parameter MenusLaser On TimeThis parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in 0.1 seco
5-22P460/P360 Memory Scanners Product Reference GuideScan Stand OptionsThe Scan Stand feature is supported only when the cord is attached to the scann
5-23Parameter MenusSelect the timeouts between decodes for the same or different symbols.1. Scan the option bar code you wish to set.2. Scan two bar c
5-24P460/P360 Memory Scanners Product Reference GuideTimeout Between Decodes (Continued)1234567890Cancel
5-25Parameter MenusBeeper OptionsBeeper ToneScan the appropriate bar code below to select a decode beep frequency (tone). Choose LOW FREQUENCY, MEDIUM
5-26P460/P360 Memory Scanners Product Reference GuideBeeper VolumeScan the appropriate bar code below to select a beeper volume. Choose LOW VOLUME, ME
5-27Parameter MenusPower Detect BeepScan the appropriate barcode below to enable or disable the Power Detection Beep.POWER DETECT BEEP DISABLEDPOWER D
5-28P460/P360 Memory Scanners Product Reference GuideBeep After Good DecodeScan the appropriate bar code below to select whether or not the scanner be
5-29Parameter MenusDecode OptionsTransmit “No Read” MessageScan the appropriate bar code below to select whether or not a “No Read” message is transmi
5-30P460/P360 Memory Scanners Product Reference GuideEnable/Disable UPC-E/UPC-A/UPC-E1Scan the appropriate bar code below to enable or disable UPC-E o
viiiP460/P360 Memory Scanners Product Reference GuideMCL-Net Frame Timeout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-31Parameter MenusEnable/Disable EAN-8/EAN-13Scan the appropriate bar code below to enable or disable EAN-8 or EAN-13.ENABLE EAN-8DISABLE EAN-8ENABLE
5-32P460/P360 Memory Scanners Product Reference GuideEnable/Disable Bookland EANScan the appropriate bar code below to enable or disable Bookland EAN.
5-33Parameter MenusDecode UPC/EAN SupplementalsSupplementals are characters (either 2 or 5) that are added on according to specific code format conven
5-34P460/P360 Memory Scanners Product Reference GuideDecode UPC/EAN Supplemental RedundancyWith Autodiscriminate UPC/EAN Supplementals selected, this
5-35Parameter MenusTransmit UPC-A/UPC-E/UPC-E1 Check DigitScan the appropriate bar code below to transmit the symbol with or without the UPC-A, UPC-E,
5-36P460/P360 Memory Scanners Product Reference GuideUPC-A PreambleThree options are given for lead-in characters for UPC-A symbols transmitted to the
5-37Parameter MenusUPC-E PreambleThree options are given for lead-in characters for UPC-E symbols transmitted to the host device: Transmit system char
5-38P460/P360 Memory Scanners Product Reference GuideUPC-E1 PreambleThree options are given for lead-in characters for UPC-E1 symbols transmitted to t
5-39Parameter MenusConvert UPC-E to UPC-AThis parameter converts UPC-E (zero suppressed) decoded data to UPC-A format before transmission. After conve
5-40P460/P360 Memory Scanners Product Reference GuideConvert UPC-E1 to UPC-AThis parameter converts UPC-E1 decoded data to UPC-A format before transmi
Comments to this Manuals