3. Grounding and lightning protection PTP 500 Installation Guide
phn-2508_005v000 (Mar 2013)
Page 12
Mast or tower installation
For mast or tower installations, the following additional requirements must be met:
• The equipment must be lower than the top of the tower or its lightning air terminal.
• The metal tower or mast must be correctly grounded.
• A grounding kit must be installed at the first point of contact between the drop cable
and the tower, near the top.
• A grounding kit must be installed at the bottom of the tower, near the vertical to
horizontal transition point, bonded to the tower or its ground bar (TGB).
• If the tower is greater than 61 m (200 ft) in height, an additional grounding kit must
be installed at the tower midpoint and as necessary to reduce the distance between
ground kits to 61 m (200 ft) or less.
• In high lightning prone geographical areas, additional ground kits should be
installed at spacing between 15 to 22 m (50 to 75 ft). This is especially important on
towers taller than 45 m (150 ft).
A schematic example of a mast or tower installation is as follows: