Motorola Command One User Manual Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 18
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
2-4 Suite56™ Parallel Port Command Converter User’s Manual Motorola
Resetting Target DSP Devices
Figure 2-4 shows two possible configurations of a second method that also enables signal
quality to meet the requirements. In Configuration Number 1, the signal is split and
buffered into a number of parallel TCKn signals. Each of these signals may drive up to
four TCK inputs.
Figure 2-4. Multiple JTAG Connectors (Parallel Method)
In Configuration Number 2, the signal is split and buffered into a number of parallel
TMSn signals. Each of these signals may drive up to four TMS inputs.
Each method is equally valid. The choice of methods will depend on practical
considerations related to each project.
2.4 Resetting Target DSP Devices
The RESET
signal and TRST signals from the command converter are typically connected
to all target DSP devices on a JTAG chain. All DSP devices on a JTAG chain connected to
a specific command converter device are reset when R
ESET and TRST are asserted by the
debugger command FORCE R. Execution control is established immediately after
TCK TCK TCK TCK
TCK TCK TCK
TCK TCK TCK TCK
TCK TCK
1
TCK
2
TCK
n
AA2040
TMS TMS TMS TMS
TMS TMS TMS
TMS TMS TMS TMS
TMS TMS
1
TMS
2
TMS
n
Configuration Number 1 —Fan Out of TCK at Source
Configuration Number 2 —Fan Out of TMS at Source
Fr
eescale S
emiconduct
or
, I
Freescale Semiconductor, Inc.
For More Information On This Product,
Go to: www.freescale.com
nc...
Page view 13
1 2 ... 9 10 11 12 13 14 15 16 17 18

Comments to this Manuals