3.5 MEASUREMENTSFROMDIAGNOSTICS
A unit-based comparison of diagnostic measurements is provided in Table 13.
Table 13: Comparison of diagnostic measurements
Measurement Description Availability Advantage Disadvantage
Bit errors Logic errors in
the bit stream
Only out of
service
Best unit for
point-to-point
performance
Requires that all traffic
be test traffic (known
data pattern)
BPVs Pulses of the
same consecutive
polarity
In service
or out of
service
Good for circuit
or repeater
problems
Meaningful for only
metallic media, because
some equipment corrects
BPVs
Frame errors Incorrect values
in the framing
bit position
In service
or out of
service
Approximates
bit error rate on
in-service basis
Evaluates only overhead
bits
CRC errors Bit errors in a
block of data
In service
or out of
service
98.4% bit error
rate accuracy
Available with only ESF
framing
3.6 FIRMWAREUPGRADES
Firmware upgrades are periodically made available to enhance performance or to add
features and functionality to the Canopy T1/E1 Multiplexer.
Procedure 29: Upgrading firmware
To install new firmware on a Canopy T1/E1 Multiplexer, perform the following steps.
1. Close any other applications that are active on the PC.
2. From the main menu of the EMS, select ConfigSoftware Upgrade (shown in
Figure 15 on Page 33).
RESULT: The System Upgrade window opens, as shown in Figure 24.
Figure 24: System Upgrade window
Issue3
Page view 58
1 2 ... 54 55 56 57 58 59 60 61 62 63 64 ... 72 73