2-56 Master Glossary of Terms and Symbols
TR4.0:PROVOX Revision A April 1997
implied valve position or pressure
(IVP)
The output of a primary control algorithm
(PCA) or a smart field device. The IVP
either determines how much to open a
valve actuator, which moves to a position,
or determines the pressure of a
transducer. Note that if the IVP is
modified by a station function or FST
after being computed by the PCA, the
valve output and the IVP will not be the
same.
import
1. For ENVOXr software: moving CDV
files into the configuration database.
2. For Recipe Manager software:
copyingarecipefromanarchivein
another database to the current
database.
INAC
1. Abbreviation: Inactive
2. Acronym: Increase To Close
INC CLO
This remote detail display parameter
(DDP) a ttribute, 10:INC CLO, shows
FIELDVUE variable 74, increase to close,
as a yes (increase close) or no (increase
open). This tunable DDP is used to
enable or disable the output signal
inversion (based on actuator type) from a
PROVUEr or Operator Workplace
console.
IND
Abbreviation: Indicator
indicator
1. An instrument that graphically shows
the value of a variable.
2. A visual readout of a measurement,
condition, or operating mode of a device,
or an alarm to get someone’s attention.
indirect control point (ICP)
A regulatory controller point type which is
composed of a set of analog or discrete
values. These values may be displayed
at a console, but are not used to directly
control a process.
indirect measurement
A procedure performed by some smart
field deivces that converts a
measurement sent in one unit of
measurement, such as pressure, to
another unit of measurement, such as
gallons. For example, a differential
pressure transmitter used to measure
gallons might actually be reading
pressure. The transmitter sends the
number of gallons in terms of pressure
and the system converts th e pressure to
gallons. This action is considered an
indirect measurement.
industrial control architecture (ICA)
A group of basic principles that guided
the design of several IBM computers.
The acronym ICA is an IBM mark.
.in file
Input sample file.
information stream
The first stream in a CDV file.
initialize
The process of bringing the software to a
state where it accepts a configuration
from the ENVOX database, or accepts a
self-download; typically, part of boot up.
2