Motorola MPC8260 User's Guide Page 140

  • Download
  • Add to my manuals
  • Print
  • Page
    / 174
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 139
138 MPC8240 and MPC8260 Emulation
Chapter 10: Troubleshooting the Emulator
Problems with the Target System
was not set in the boot code. This can be fixed by ’ORing’ in
0x00000002 into the SRR1 register and resuming the run.
If you see the “!ERROR 145!” error message
If the following error arises:
!ERROR 145! Unable to soft stop - freezing the processor
clocks
The processor is in an unstable state and should be reset via a hard
reset or a power-on reset. The 'rst' command may not be able to bring
the processor into a known state.
Other error messages
The following is a list of unique error messages that may be
encountered for this product.
!ERROR 644! Could not update IMMR register
!ERROR 644! cf_immr does not match actual IMMR
!ERROR 644! Unable to modify SYPCR register
Refer to “Configuration registers” on page 81
!ERROR 644! Register <reg> does not match its shadow segment register
To synchronize the segment register with its shadow register, write a
value to the segment register. For example: m>reg sr0=0.
Page view 139
1 ... 139 140 141 ... 174

Comments to this Manuals