FOMA® M702iGManual for Data CommunicationData Communications ...
9aClick "スタート (Start)" y "コントロールパネル (Control Panel)" then click "パフォーマンスとメンテナンス (Performance and Maintenance)" y "シ
10• Check that no other software is running before installing the FOMA PC configuration software. Terminate any running software before installing the
11Uninstall the old version of W-TCP environment configuration software from the "プログラム追加と削除 (Add or Remove Programs)" (for Windows 2000, &q
12cSelect "COMポート指定 (Specify COM port)" y Click the "COM:" field to set the COM port number assigned to the FOMA handset• A COM po
13fSelect any users under "使用可能ユーザーの選択 (Select a permitted user)" and click [次へ (Next)]To connect to "mopera U" or "mopera&qu
14kSet "最適化を行う (Optimize)" to y Click [次へ (Next)] If already optimizedA conformation to optimize does not appear. Go to Step 12.lCheck th
15Using Another ProvideraOn the FOMA PC configuration software screen, click [かんたん設定 (Easy Settings)]bSelect "64Kデータ通信 (64K Data Communication)&q
16 For Windows 2000Click "スタート (Start)" y "プログラム (Programs)" y "アクセサリ (Accessories)" y "通信 (Communication)" y
17cSet to a dial-up connection to optimize y Click [実行 (Execute)]• Set to a dial-up connection to cancel optimizing.dFollow the instructions on th
18Writing APN Information to the FOMA HandsetYou can write the APN settings that have been written to the FOMA handset, to the FOMA handset.aClick [FO
1Data CommunicationsConnecting the FOMA handset and a PC allows you to use three types of data communications (packet communication, 64K data communic
19eClick [完了(Finish)]The un-installation of the FOMA PC configuration software completes. If W-TCP settings have been optimizedThe following screen i
20eClick [キャンセル (Cancel)] on the Connection screenThe Hyper Terminal entry screen opens.fEnter the APN in the following format y Press [Entry Format]A
21bOn the New connection wizard screen, click [次へ (Next)]cSelect "インターネットに接続する (Connect to the Internet)" y Click [次へ (Next)]dSelect "接
22nClick the "ネットワーク (Network)" tab y Set as the example on the screen• Select "PPP:Windows 95/98/NT4/2000,Internet" in the "
23jEnter the APN phone number in the "電話番号 (Phone Number)" field y Click [詳細設定 (Advanced settings)]• When you connect "mopera U",
24sCheck the settings on the "全般 (General)" tab screen• If two or more models are connected to the PC, set only "Modem -FOMA M702iG&quo
25bEnter "ユーザー名 (User Name)" and "パスワード (Password)" y Click [ダイヤル (Dial)]The access point will be connected.• To connect to "
26AT CommandsAT commands are used to check the FOMA handset function settings or status using a PC. Usually the communication software issues AT comma
27AT Command ListThe following AT commands can be used on the "FOMA M702iG" modem port.• [&F] : A command to initialize settings used as
28AT&E<n>[&F] Select the specification to show the connection speed.n=0 : Show the communication speed for wireless segment.n=1 (default
2• Access points for PHS 64K/32K data communication for PIAFS, etc. cannot be connected. User Authentication to Access NetworksDepending on the acces
29AT+CAOC=<mode>[?] [=?]Inquire the current billing value. mode=0 : Check the current billing value for the calls.Execute AT+CAOC or AT+CAOC=0 t
30AT+CGREG=<n>[&F] [?] [=?]Set whether to be notified of the network registration status.n=0 (default): Do not notify.n=1 : Notify when outs
31AT+CMEE=<n>[&F] [?] [=?]Set the error report format of the FOMA handset.n=0 (default): Display “ERROR”.n=1 : Display in the format of “+CM
32AT+CPAS[=?]Display FOMA handset state. Executing “AT+CPAS” displays in the format of “+CPAS : <n>”.n=0 : Available to set AT commands.n=1 : Un
33AT+CREG=<n>[&F][?] [=?]Set whether to show Out of service area or in the service area.n=0 (default): Hiden=1 : ShowEnter “AT+CREG?” then i
34AT+IFC=<n>,<m>[&F][?] [=?]Set the local flow control method between the PC and the FOMA handset.n : DCE by DTE controln=0 : No flow
35ATS0=<n>[&F] [?]Set number of rings until FOMA handset receives connection automatically.n=0 (default): No auto receive is performed.n=1 t
36ATX<n>[&F] Set to detect the busy tone and dial tone, and to display the communication speed.n=0 : Not to detect busy tones, not to detect
37Supplementary Explanation of AT Commands Command name : +CGDCONT• OverviewSet APN when sending packet connection.•Form+CGDCONT=[<cid>[,“<P
38default cid1 is registered "mopera.ne.jp" for APN of "mopera" and cid3 is registered "mopera.net" for APN of "mop
3Required DevicesTo use data communications, the following are required in addition to the FOMA handset and a PC:• FOMA USB Cable (optional)*• FOMA mi
39 Communication Protocol Result Codes Examples of Displayed Result CodesWhen ATX0 is setRegardless of the AT¥V command (P27) settings, only CONNECT
4FOMA PC configuration softwareThis software is to be installed on a PC to quickly configure settings of dial-up connections, etc. that are required t
5 If the screen to recommend the installation interruption is displayedClick [続行 (Continue)] to continue the installation. The M702iG communication c
6cPlug the USB connector of the FOMA USB Cable to a USB connector on the PC• Use the exclusive FOMA USB Cable to connect the FOMA handset and PC. A co
7• If the FOMA USB Cable (optional) was disconnected or the installation was cancelled by pressing [キャンセル (Cancel)] on the PC screen while the M702iG
8Make the Device Registration of the FOMA Handset and PCAfter the FOMA handset become search ready, search for the FOMA handset from the PC, register