Motorola 388 Service Manual Page 32

  • Download
  • Add to my manuals
  • Print
  • Page
    / 47
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 31
Level 1-2 Service Manual
May 30, 2008 32
Troubleshooting Chart
Table 4: Level 1 and 2 Troubleshooting Chart
Symptom Probable Cause Verification and Remedy
1. Telephone will not turn on or stay on. a) Battery either discharged or
defective.
Measure battery voltage across a 50 ohm (>1
Watt) load. If the battery voltage is <3.25 Vdc,
recharge the battery using the appropriate
battery charger. If the battery will not
recharge, replace the battery. If battery is not
at fault, proceed to b.
b) Battery terminals open or mis-
aligned.
Visually inspect the battery terminals on both
the battery and the telephone. Realign and, if
necessary, either replace the battery or refer
to a Level 3 Service Center for the battery
connector replacement. If battery terminals
are not at fault, proceed to c.
c) keypad defective. Replace the keypad. Temporarily connect a
+3.6 Vdc supply to the battery terminals.
Press and hold the PWR button. If unit turns
on and stays on, disconnect the dc power
source and reassemble with the new keypad.
2. Telephone exhibits poor reception or
erratic operation such as calls frequently
dropping or weak or distorted audio.
Connections to or from lower PCB
defective.
Check connection between the antenna and
the lower PCB.
3. Display is erratic, or provides partial
or no display.
LCM defective. Replace the LCM. Verify that the fault has
been cleared and reassemble the unit with
the new LCM.
4. Incoming call alert transducer audio
distorted or volume is too low.
Speaker defective. Replace the speaker as described in the pro-
cedures. Verify that the fault has been
cleared and reassemble the unit with the new
speaker.
5. Telephone transmit audio is weak.
(usually indicated by called parties com-
plaining of difficulty in hearing voice).
Microphone defective. Replace the microphone as described in the
procedures. Verify that the fault has been
cleared and reassemble the unit with the new
microphone.
6. Receive audio from earpiece speaker
is weak or distorted.
a) Connections to or from lower
PCB defective.
Check connection between the antenna and
the lower PCB. If the connection is OK, pro-
ceed to b.
b) Speaker defective. Temporarily replace the speaker with a
known good speaker. Ensure good connec-
tion. Place a call and verify improvement in
earpiece audio. If fault is cleared, reassemble
the telephone with the good speaker.
Page view 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 ... 46 47

Comments to this Manuals

No comments